Esp Control - Harman XXV Owner's Manual

Pellet stove
Table of Contents

Advertisement

autOMatic ignitiOn eSP cOntrOl
Dealer Diagnostic Port
For dealer maintenance
only. Requires special DDM
monitor supplied to Harman
Dealers exclusively.
D i s t r i b u t i o n B l o w e r
speed adjustment range.
L = low
H = high
Variable speed anywhere
between L and H; although
as the stove temp. goes
up, so does the low end
of the scale.
Mode Selector
Allows you to choose
b e t w e e n R o o m Te m p
Mode, Stove Temp Mode,
or OFF. Also allows you to
vary the distribution blower
speed by turning the knob
to the high or low side of
each mode.
Igniter switch
Set to appropriate Start-
Up mode.
Test
Runs all motors at full
speed for one minute
t o c h e c k o p e r a t i o n .
Afterwards, the stove will
be at minimum draft and
will remain there as long
as you are still in "Test
Mode".
Status light error messages:
3 blinks: Indicates that the ESP (Exhaust Sensing
Probe) has gone out of range too many times. If the
stove seems to be operating correctly, perform a
manual reset*. May indicate a need for cleaning, es-
pecially the exhaust / venting system.
4 blinks: Can occur only in Room Temp Mode and
indicates Room Sensing Probe failed or not installed.
If a Room Sensing Probe is then installed, the status
light will automatically reset.
5 blinks (in igniter auto. Mode Only): Indicates that
the unit has failed to light within the 36 minute start
cycle. To reset - Turn Mode Selector to "OFF", then
turn to either mode again.
16
XXV Pellet Stove
Feed adjuster
Sets the maximum feed rate
per each cycle of the control.
Power Light
Indicates power to the control.
6 blinks : Indicates that the control has calculated
poor or incomplete combustion occurring for more
than 50 minutes.
A six blink status may be set if the stove is allowed
to run out of pellets. To reset, turn mode selector to
"OFF" then back on to the desired mode. If the unit
was not out of pellets, see Troubleshooting section
for more details.
* Manual reset- disconnect the power cord for a few
seconds and reconnect. If error still occurs call your
Dealer.
Temp dial
Allows you to adjust the
room temperature in
Room Temp Mode using
the outer scale marked
in degrees Fahrenheit. It
also allows you to adjust
the stove temperature
while in Stove Temp
Mode using the inner
scale marked from 1
to 7.
Indicates power to the
igniter
Indicates power to the
feed motor.
Indicates power to
combustion blower
Indicates power to
distribution blower.
Status Light
Will be lit in either stove
or room temp mode when
pointer is not within off
position band except
after normal shut down.
Blinks to indicate errors
listed below.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents