Magnetometer Troubleshooting - Nokia RM-596 Service Manual

Hide thumbs Also See for RM-596:
Table of Contents

Advertisement

RM-596
BB Troubleshooting and Manual Tuning Guide

Magnetometer troubleshooting

Equipment
• Non-magnetic, horizontal table
• nearest ferromagnetic part, distance more than 50 cm
• Traditional needle type compass for reference
• Rotating platform (sheet of wood or plastic)
• PC with Phoenix
Preparation of phone
• Set the rotating platform to the table
• Set the phone and reference compass to the rotating platform
• Connect the phone to the PC and start Phoenix
Tests
• General troubleshooting test
• Self-test (ST)
• Azimuth check test
Page 3 – 44