Viessmann VITODENS 200-W Installation And Service Instructions Manual page 61

Wall mounted gas condensing boiler
Table of Contents

Advertisement

General/group "1"
(cont.)
Value ad-
System ver-
dress 00: ...
sion
2
1
3
2,3
4
2,3
5
4
6
4
7
4
8
4
9
4
10
4
Coding in the delivered condition
11:≠9
No access to the coding addresses
for the combustion controller pa-
rameters
25:0
Without outside temperature sen-
sor (for constant temperature con-
trol units)
2A:0
Without wireless outside tempera-
ture sensor
2d:1
With flow sensors (do not adjust)
32:0
Without AM1 extension
33:1
Function output A1 at AM1 exten-
sion: Heating circuit pump
34:0
Function output A2 at AM1 exten-
sion: DHW circulation pump
35:0
Without EA1 extension
36:0
Function output
sion: Fault message
39:2
Function output
pump for cylinder heating
Description
One heating circuit without mixer A1 (heating circuit 1), with DHW heating (code is
set automatically)
One heating circuit with mixer M2 (heating circuit 2), without DHW heating
One heating circuit with mixer (heating circuit 2), with DHW heating
One heating circuit without mixer A1 (heating circuit 1) and one heating circuit with
mixer M2 (heating circuit 2), without DHW heating (code is set automatically)
One heating circuit without mixer A1 (heating circuit 1) and one heating circuit with
mixer M2 (heating circuit 2), with DHW heating (code is set automatically)
One heating circuit with mixer M2 (heating circuit 2) and one heating circuit with
mixer M3 (heating circuit 3), without DHW heating
One heating circuit with mixer M2 (heating circuit 2) and one heating circuit with
mixer M3 (heating circuit 3), with DHW heating
One heating circuit without mixer A1 (heating circuit 1), one heating circuit with
mixer M2 (heating circuit 2) and one heating circuit with mixer M3 (heating circuit
3), without DHW heating (code is set automatically)
One heating circuit without mixer A1 (heating circuit 1), one heating circuit with
mixer M2 (heating circuit 2) and one heating circuit with mixer M3 (heating circuit
3), with DHW heating (code is set automatically)
at EA1 exten-
aBJ
: Circulation
sA
Possible change
11:9
Access open to the coding address-
es for the combustion controller pa-
rameters
25:1
With outside temperature sensor
(automatic recognition)
2A:1
With wireless outside temperature
sensor (automatic recognition)
2A:2
Wireless outside temperature sensor
not used
32:1
With AM1 extension (automatic rec-
ognition)
33:0
Function output A1: DHW circulation
pump
33:2
Function output A1: Circulation
pump for cylinder heating
34:1
Function output A2: Heating circuit
pump
34:2
Function output A2: Circulation
pump for cylinder heating
35:1
With EA1 extension (automatic rec-
ognition)
36:1
Function output
36:2
Function output
tion pump
39:0
Function output
pump
39:1
Function output
pump
Code 2
: Feed pump
aBJ
: DHW circula-
aBJ
: DHW circulation
sA
: Heating circuit
sA
61