Vitodens 222-F B2TB 19 and 35 Service

Start-up and Shutdown

Legend
A Fault indicator (red)
B ON indicator (green)
C Reset button
D ON/OFF switch
E Pressure gauge

Menu

There are two control levels available, the "Standard menu" and the "Extended menu".
Legend
A Header (shows the heating program for displayed
heating circuit D)
B Current outside temperature
C Set room temperature
D Heating circuit which is selected for operation
in the standard menu
Outdoor Reset Programming Unit
Starting the heating system
1. Check the heating system pressure at the pressure
gauge. The heating system pressure is too low if
the indicator points to the area below 15 psi.
In this case, top up with water or notify your local
heating contractor.
2. For room air dependent operation:
Check that the ventilation apertures of the boiler
room are open and unrestricted.
Note: With room air dependent operation, the
combustion air is drawn from the boiler
room.
3. For Vitodens:
Open the gas shut-off valve.
Note: Ask your heating contractor to explain the
positioning and handling of these components.
4. Switch ON the power supply, e.g. at a separate
MCB/fuse or a mains isolator.
5. Turn the ON/OFF switch "8" ON. After a short time,
the standard menu is displayed (see below) and
the green ON indicator illuminates. Your heating
system and, if installed, your remote controls are
now ready for operation.
Note: Slide the black control cover outwards to
access the ON/OFF switch.
Standard menu
Note: If your heating system has 2 or 3 heating circuits:
You can select the heating circuit "HC1", "HC2"
or "HC3" to be displayed in the standard menu
(see page 65).
If your heating system only has 1 heating circuit:
No heating circuit name "HC..." is shown in the
header.
In the standard menu, you can adjust and scan the most
frequently used settings for the heating circuit shown in
the header:
Press the following keys to set room temperature:
for the required value
to confirm
OK
Heating programs:
Standby mode with frost protection monitoring
9
Only DHW
w
wz Heating and DHW
Press the following keys:
for the required heating program
to confirm
OK
Note: 2 minutes after any setting has been made, the
display automatically reverts to the standard menu.