Complete Installation; Gas Conversions; Lp Gas Conversion - Jenn-Air JDRP548W Installation Instructions Manual

Commercial-style dual fuel convection ranges
Hide thumbs Also See for JDRP548W:
Table of Contents

Advertisement

Available languages

Available languages

Complete Installation

1. Check that all parts are now installed. If there is an
extra part, go back through the steps to see which
step was skipped.
2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials.
4. For oven use and cleaning, read the Use and Care Guide.
Check Operation of Oven(s)
1. Turn power ON.
2. Start a Bake cycle. See the Use and Care Guide for
operating instructions.
If oven(s) does not operate, check the following:
Household fuse is intact and tight or circuit breaker
has not tripped.
Electrical supply is connected.
See "Troubleshooting" section in the Use and
Care Guide.
IMPORTANT: Gas conversions from Natural gas to LP gas
must be done by a qualified installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
18
3. When oven has been on for 10–15 minutes, open the oven
4. Touch OFF.
To set the clock and other oven functions, refer to the Use
and Care Guide.
If you need Assistance or Service:
Please reference the "Assistance or Service" section of the
Use and Care Guide or contact the dealer from whom you
purchased your range.

GAS CONVERSIONS

1. Turn the manual shut-off valve to the closed position.
2. Unplug range, or disconnect power.
door and feel for heat.
If you do not feel heat or if an error code ("F" followed by
a number plus "E" followed by a number) appears in the
display, turn off the oven and contact a qualified technician.

LP Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
A. To range
B. Shut-off valve (closed position)
C. Gas supply line
B

Advertisement