STEINEL IS 360 W Installation Instructions Manual page 4

Ceiling mount outdoor occupancy sensor
Table of Contents

Advertisement

Available languages

Available languages

4
Mounting
Placement guidelines
• Intended for surface mounting
under soffi t (exterior) or on
ceiling (interior)
• Ideal outdoor placement for the
IS 360 is under an overhang
• Detection lens must have a clear,
unobstructed view of detection
area
• Ideal mounting height is
8-12 feet
Installation
Ensure use of the correct enclosure
and confi rm power is off at the
circuit breaker.
• Remove housing cover. Press
the two indentations on side
of housing cover, turn counter-
clockwise and pull.
www.steinel.net
(800) 852-4343
Junction box
Mounting plate
1
Sensor housing
2
Fastening screw
Housing cover
4
Decorative ring
3
• Backout the 2 fastening screws;
separate sensor housing from
mounting plate.
• Insert the two rubber plugs into the
mounting plate.
• Place the sensor wires through
the knockout in the center of
the mounting plate and connect
electrical wires (see Wiring).
• Align mounting plate with junction
box and secure with j-box screws.
• Realign mounting plate to sensor
housing; secure with fastening
screws.
• Reapply and engage the housing
cover.
(Note: The device housing is not
suitable for fi eld wiring termination.)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Is 360 b

Table of Contents