Kärcher BR 40/25 C Bp Manual page 28

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
Fault
Appliance cannot be
started
Insufficient water quan-
tity
Insufficient vacuum per-
formance
Insufficient cleaning re-
sult
Brushes do not turn
28
Faults without display
Remedy
Check battery; charge it, if needed
Check battery pole fuse at the positive pole of the battery (75 A);
inform customer service if the fuse is defective.
Check fresh water level, refill tank if necessary.
Check hoses for blockages; clean if required.
Check the condition of the seals between waste water tank and
cover, replace if required.
Clean the fluff filter
Clean the vacuum lips on the vacuum bar, turn or replace if re-
quired
Check suction hose for blockages; clean if required.
Check the suction hose for tightness; replace if required.
Check if the cover on the dirt water discharge hose is closed
Check the setting of the vacuum bar.
Check the brushes for wear, replace if required.
Check if foreign matters block the brushes; remove foreign matter
if required.