BLOWER EXHAUST DIRECTION

The blower assembly may be rotated 90 degree clockwise
or counterclockwise to allow horizontal venting in areas
having restricted space above the water heater. To rotate
the blower outlet, remove the four nuts (with 11/32" nut
driver) (see Figure 35), securing the fl ue collector to the
blower housing. Pull the blower assembly forward to free
it from the mounting studs. Rotate the blower housing
clockwise or counter-clockwise and align the four holes
and screws together. Reattach the blower housing to the
fl ue collector.
Note: Coupling to vent system
not shown for clarity.
Figure 35
WARNING
Fire or Explosion Hazard
• Do not store or use gasoline or other flammable vapours
and liquids in the vicinity of this or any other appliance.
• Avoid all ignition sources if you smell gas.
• Do not expose water heater control to excessive gas
pressure.
• Use only gas shown on rating plate.
• Maintain required clearances to combustibles.
• Keep ignition sources away from faucets after extended
period of non-use.
Read instruction manual before
installing, using or servicing
water heater.
30
11/32" nut
331432-001