Pump Oil Cap And Pump Component Identification; Operation Instructions; Water Supply - North Star M1573001A Owner's Manual

Machine that cleans dirty surfaces with high pressure water
Table of Contents

Advertisement

Water Supply

1.) Make sure the water supply is clean.
performance.
2.) An insufficient water supply will damage your pump. Make sure the water supply is steady and is
20% over the rated flow of your pump. Use a stopwatch to time how long it takes to fill a 5 gallon
bucket with your garden hose. The bucket must fill faster than the times listed in the table below.
3.) The water supply garden hose must have an inside diameter of at least 5/8". If the hose is more
than 100 ft. long, the diameter must be at least 3/4".
4.) Never use a reservoir tank as a water source. Drawing water out of a tank may cause pump
cavitation and damage to your pump. This pressure washer is designed for a pressurized water
source such as a city water faucet. However, the water source pressure must not exceed 115 psi
(8 bar).
5.) Always use a flexible rubber hose for your water supply. Do not use rigid piping.
Pump Component Identification
1573001

Operation Instructions

Model
1573001
1573011
1573021
Debris can cause excess pump wear and reduce
Time to fill 5 gallon bucket
150 seconds
160 seconds
96 seconds
1573011 & 1573021