Magellan 3300HSi In-Counter Horizontal Single Plane Scanner Product Reference Guide...
Page 2
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC, Inc. or its subsidiar- ies or affiliates ("Datalogic"...
Table of Contents Chapter 1. Getting Started................................1 About This Manual ....................................1 Manual Conventions ........................................1 Connecting the Scanner ..................................2 Error Codes ......................................4 Installation ......................................4 LED and Beeper Indicators ..................................6 Programming .......................................8 Using the Programming Bar Codes ..................................8 Resetting the Standard Product Defaults ..............................8 Data Matrix Programming Labels ................................8 Bar Code Mask ....................................9 Going Green ..........................................10...
Page 4
Set Single Cable RS-232 STX Character ................................61 Single Cable RS-232 Use ETX ....................................62 Set Single Cable RS-232 ETX Character ................................62 Single Cable Pacesetter Plus ....................................63 Single Cable Datalogic Extensions ..................................63 USB-OEM Interface Features ....................................64 USB-OEM Device usage ....................................64 IBM ..............................................64 IBM Transmit Labels in Code 39 Format ..............................64...
Page 6
MSI Check Character Calculation ..................................124 MSI Number of Check Characters ..................................124 MSI Length Control .........................................125 MSI Length 1, Length 2 Programming Instructions ............................125 Chapter 7. 2D Symbologies ................................. 127 2D Symbologies ....................................127 PDF 417 ............................................128 Disable/Enable PDF 417 ....................................128 Allow Zero Length PDF 417 Reading ..............................128 Length Control ........................................129 PDF 417 Length 1, Length 2 Programming Instructions .........................130 Micro PDF 417 ...........................................131...
Page 7
Application code load to scanner ................................184 Configuration load to scanner .................................. 185 Appendix I. Handheld Data Format Requirements....................187 Handheld Data Format Requirements General ............................187 Datalogic Handheld Data Format Requirements ............................188 RSS-14 ..........................................188 RSS Expanded ......................................... 188 UPC-A ..........................................188 UPC-A with 2-Digit Supplemental ................................
Chapter 1 Getting Started The Magellan 3300HSi Horizontal Single Plane Scanner is designed for small counter retail checkout environments where there is a relatively high number of transactions with a fairly small number of items per transaction. The scanner has a reduced footprint, allowing more room for item merchandising of high margin impulse items clustered around the P.O.S.
Getting Started Connecting the Scanner The scanner kit you ordered to match your interface should provide a compatible cable for your installation. Alternatively, if your scanner receives Power Off the Terminal (POT) it might be possible to connect using a cable from a previously existing installation (except for USB). If you wish to connect using an existing cable, but cannot use POT, a short adapter cable is available.
Page 11
Connecting the Scanner Connect the scanner to a USB port on the terminal/PC using the correct USB Connection — Figure 1 USB cable for the interface type you ordered. Reference USB installations may require a power connection via an approved A/C Adapter as shown in Figure 1b or...
Getting Started Error Codes If an error is detected, the scanner will sound a long low tone (for three seconds) and flash its LED, indicating a failure. When this occurs, remove the top cover and press the Scanner Push Button to hear the error code. If it is configured to do so, the scanner will sound a series of beeps corresponding to the error code and/or flash its LED simultaneous to the beeps.
Installation 6. Connect the interface cable to the terminal. 7. If required, connect the scanner’s AC Adapter to the AC outlet. 8. Switch the terminal ON. 9. Verify operation by scanning a few known-good bar code labels. The scanner should now be communicating the bar code data to the POS terminal.
Getting Started LED and Beeper Indicators The scanner’s beeper sounds and its green LED illuminates to indicate various functions or errors on the scanner. The tables below list these indications. One exception to the behaviors listed in the tables is that the scanner’s functions are programmable, and may or may not be turned on.
Page 15
LED and Beeper Indicators LED and Beeper Indicators — cont. Table 2. Beeper Functions BEEPER INDICATION COMMENT INDICATION Power On Beep Single beep The Power-On Beep indication is a configurable feature which can be enabled or disabled. When enabled, this beep Indicates the scanner has finished all its power up tests and is now ready for operation.
Getting Started Programming The scanner is typically factory-configured with a set of default features standard to the interface type you ordered. After scanning the interface bar code from the Interface Related Features sec- tion, you can select other options and customize your scanner through use of the instructions and programming bar codes available in that section and also the Data Editing Symbologies...
Bar Code Mask Bar Code Mask Cut a hole in this page and remove it from the manual as indicated to create a sleeve through which bar codes (starting in the following section) can be individually viewed and scanned. It is important that only one bar code at a time be presented to the scanner.
Getting Started Going Green Thank you for using the bar code mask on the opposite side of this page. This manual has been formatted to minimize the quantity of pages needed to provide all of the programming bar codes available for this product. LED Class CLASS 1 LED PRODUCT APPARECCHIO LED CLASSE 1 LED KLASSE 1 APPAREIL A LED DE CLASSE 1...
Chapter 2 General Features Double Read Timeout for Linear Labels This Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same linear label again (e.g. two identical items in succession). START / END PROGRAMMING bar codes 0.1 Second 0.2 Second...
Page 20
General Features Double Read Timeout for Linear Labels — cont. START / END PROGRAMMING bar codes 0.7 Second 0.8 Second 0.9 Second 1 Second Magellan 3300HSi...
Double Read Timeout for 2D Labels Double Read Timeout for 2D Labels This Double Read Timeout feature specifies the minimum allowable time between consecutive good reads of the same PDF 417, Micro PDF 417 Data Matrix, QR Code, Maxicode, Aztec or Composite label.
General Features Scanner Button Options This feature allows the user to configure the scanner / volume button (which is accessible under the removable top cover) to different modes of operation. Options are: • All functions (volume, tone, diagnostics, and reset) •...
Controls the function associated with the "Picture Taking" button This is an optional feature. In order to use it, an accessory “Remote Camera Button” (available from Datalogic) will need to be inserted into the scanner’s auxiliary port. NOTE Options are: •...
General Features LED Level This feature defines the LED intensity level by pulse width. START / END PROGRAMMING bar codes LED Level = DEFAULT LED Level = Low Magellan 3300HSi...
Auxiliary Port Mode Auxiliary Port Mode Specifies the function associated with the auxillary interface. Choices are: • Disabled • 01=Serial Handheld Enabled • 02=PIR/CT Output plus Diagnostics Reporting START / END PROGRAMMING bar codes Disable Auxiliary Port Mode DEFAULT Auxiliary Port Mode = Serial Handheld Enabled Auxiliary Port Mode = PIR/CT Output plus Diagnostics Reporting Product Reference Guide...
General Features Auxiliary Port Baud Rate Specifies baud rate of auxillary port when operating in PIR/CT mode. START / END PROGRAMMING bar codes Auxiliary Port Baud Rate = 1200 Auxiliary Port Baud Rate = 2400 Auxiliary Port Baud Rate = 4800 Auxiliary Port Baud Rate = 9600 Auxiliary Port Baud Rate = 19200 DEFAULT...
Productivity Index Reporting (PIR) Productivity Index Reporting (PIR) When PIR is enabled, label quality data is appended to decoded data before being presented to the POS. The PIR feature allows the scanner to provide information to an external computer, indicating how easy the label was to read. This value-added feature is a factory-pro- grammed option.
General Features Sleep Mode This feature specifies the amount of time with no bar code reads before the scanner enters sleep mode. START / END PROGRAMMING bar codes Disable Sleep Mode 15 Seconds 30 Seconds 1 Minute 2 Minutes 3 Minutes 4 Minutes 5 Minutes DEFAULT...
General Features Wake Up Intensity This feature indicates the percentage of ambient light change which will trigger the scanner to wake up from Sleep Mode. Lower settings provide greater sensitivity. The selectable range for this setting is 5% to 15%. START / END PROGRAMMING bar codes DEFAULT...
Page 31
Sleep Mode Wake Up Intensity — cont. START / END PROGRAMMING bar codes Product Reference Guide...
General Features LED and Beeper Indicators Power On Alert Disables or enables the indication (a single beep) that the scanner has finished all its power up tests and is now ready for operation. START / END PROGRAMMING bar codes Disable Enable DEFAULT External Read Indicator (ERI) Active State High...
LED and Beeper Indicators ERI Timeout Specifies the amount of time the External Read Indicator (ERI) signal is held active for a good read. START / END PROGRAMMING bar codes Sets the ERI timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds).
General Features Good Read: When to Indicate This feature specifies when the scanner will provide indication (beep and/or flash its green LED) upon successfully reading a bar code. Choices are: • Good Read = Indicate after decode • Good Read = Indicate after transmit •...
LED and Beeper Indicators Good Read Beep Control This feature enables/disables the scanner’s ability to beep upon a successful decode of a bar code. START / END PROGRAMMING bar codes Disable Enable DEFAULT Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below.
General Features Good Read Beep Length Specifies the duration of a good read beep. START / END PROGRAMMING bar codes 60msec 80msec DEFAULT 100msec 120msec 140msec 160msec 180msec 200msec Magellan 3300HSi...
LED and Beeper Indicators Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels. START / END PROGRAMMING bar codes Medium High DEFAULT Product Reference Guide...
General Features Cell Phone Mode Cell Phone Mode enables the scanner to read bar codes on a cell phone display. (See Camera But- ton Mode on page 15. Use either the Camera Button accessory cable, or host command to control Cell Phone Reading Mode.
Chapter 3 Image Capture Image Capture How to Capture an Image There are two methods of capturing images as discussed below: • Image Capture to a microSD Card by Scanning a Special Label • Image Capture to the Host by Host Command •...
Image Capture Image Capture to the Host by Host Command This feature is only available for RS-232 and USB COM interfaces. If the USB COM interface has been selected, follow the USB COM instructions in the chapter Interface Set-up Interface Related Features of this guide.
Image Capture Image Capture to a microSD Card by Optional Remote Camera Button Press This feature is only available if the Camera Button is configured as image capture, optional Remote Camera Button and a microSD card is inserted. NOTE Ensure a Remote Camera Button is connected to the auxiliary port, then insert a microSD card into the scanner.
Image Capture Image Compression Specifies the starting image compression factor for JPEG images. A higher number specifies a higher quality image with less compression than a relative lower number for the same image. A value of 100 means minimal compression. A value of 1 means maximum compression at a loss of quality.
Image Capture Image Brightness This feature sets the image brightness value. Follow these instructions to configure this feature: 1. Scan the START bar code. 2. Scan the Set Image Brightness bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the two digits (zero-padded) representing the desired brightness in decimal notation.
Chapter 4 Interface Related Features Table 4-1 At the time of this writing, the reader supports the interfaces listed in . Select the desired interface type from the table, then reference the page number given for the customizable Table 4-2 features section associated with each interface.
Interface Selection Interface Selection START / END PROGRAMMING bar codes RS-232 Standard RS-232 Wincor-Nixdorf IBM 4683 Port 5B IBM 4683 Port 9B IBM 4683 Port 17 USB-OEM USB Keyboard USB COM Interface Product Reference Guide...
Page 48
Interface Related Features Interface Selection — cont. START / END PROGRAMMING bar codes Keyboard Wedge A Keyboard Wedge B Keyboard Wedge C Keyboard Wedge D Keyboard Wedge E Keyboard Wedge F Keyboard Wedge G Keyboard Wedge H ³ 0 0 0 1 3 2 Keyboard Wedge I Keyboard Wedge J Magellan...
Interface Features Interface Features Obey/Ignore Host Commands When set to ignore host commands, the scanner will ignore all host commands except for the minimum set necessary to keep the interface active and transmit labels For normal operation of the interface, select Obey Host Commands. START / END PROGRAMMING bar codes Obey Host Commands...
Interface Related Features Interface Features — cont. Host Transmission Buffers Specifies the number of host transmission(s) that may be buffered. By buffering data from a bar code, the scanner can continue to read a new bar code while the old one is being transmitted to the host.
Interface Features RS-232 Interface Features START / END PROGRAMMING bar codes Buad Rate 1200 Baud 2400 Baud 4800 Baud 9600 Baud DEFAULT 19200 Baud ³ 38400 Baud 57600 Baud 115200 Baud Product Reference Guide...
Page 52
Interface Related Features RS-232 Interface Features — cont. START / END PROGRAMMING bar codes Data Bits 7 Data Bits 8 Data Bits DEFAULT Stop Bits 1 Stop Bit DEFAULT 2 Stop Bits Parity Parity = None DEFAULT Parity = Even Parity = Odd Magellan 3300HSi...
Interface Features RS-232 Interface Features — cont. Hardware Flow Control The scanner transmits to the host regardless of any activity on the Disable Hardware Control— CTS line. The CTS signal controls transmission of data to the host. Enable CTS Flow Control— The CTS line must be active for the scanner to read and transmit data.
Interface Related Features RS-232 Interface Features — cont. Intercharacter Delay This delay is inserted after each data character transmitted. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly.
Interface Features Intercharacter Delay — cont. START / END PROGRAMMING bar codes Interchar Delay = 80 msec Interchar Delay = 90 msec Software Flow Control Disables/Enables software control using XON/XOFF characters. START / END PROGRAMMING bar codes Disable Software Flow Control DEFAULT Enable Software Flow Control Product Reference Guide...
Interface Related Features RS-232 Interface Features — cont. Host Echo When enabled, this feature passes all data through the scanner to the host as it comes in. This feature is used for applications where “daisy chaining” of RS-232 devices onto the same cable is necessary.
Interface Features RS-232 Interface Features — cont. Host Echo Quiet Interval This setting specifies the time interval of RS-232 channel inactivity which must transpire before the scanner will break the host echo loop to transmit the bar code data that has just been scanned to the host.
Interface Related Features Host Echo Quiet Interval — cont. START / END PROGRAMMING bar codes Host Echo Quiet Interval = 80msec Host Echo Quiet Interval = 90msec Host Echo Quiet Interval = 100msec Signal Voltage: Normal/TTL Specifies whether the RS-232 interface provides TTL levels on the output pins TxD and RTS. START / END PROGRAMMING bar codes Signal Voltage: Normal RS-232...
Interface Features RS-232 Invert Enables/disables inversion of RS-232 TXD and RXD signals. START / END PROGRAMMING bar codes Disable RS-232 Invert DEFAULT Enable RS-232 Invert Beep on ASCII BEL Enables/disables ability of scanner to beep (sound a good read tone) on receiving an ASCII BEL (07 hex).
Interface Related Features Beep on Not on File Select for the host to beep (or not) when a not-on-file (host command) condition is detected by the host. START / END PROGRAMMING bar codes Disable Beep on Not On File Enable Beep on Not On File DEFAULT Magellan 3300HSi...
Interface Features ACK NAK Options This enables/disables the ability of the scanner to support the RS-232 ACK/NAK protocol. When configured, the scanner and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Selections for this option are: •...
Interface Related Features RS-232 Interface Features — cont. ACK Character START / END PROGRAMMING bar codes Sets the ACK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in “005”. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set ACK Character,”...
Interface Features RS-232 Interface Features — cont. Retry on ACK NAK Timeout Enables/disables retry after the configurable ACK NAK Timeout Value (set in the following fea- ture) has expired. START / END PROGRAMMING bar codes Disable Retry on ACK NAK Timeout Enable Retry on ACK NAK Timeout DEFAULT ACK NAK Timeout Value...
Interface Related Features RS-232 Interface Features — cont. ACK NAK Retry Count START / END PROGRAMMING bar codes This feature sets the number of times for the scanner to retry a label transmission under a retry condition. 000 = No retry 001 - 254 = Retry for the specified number of times...
Interface Features RS-232 Interface Features — cont. ACK NAK Error Handling This item specifies the method the scanner will use to handle errors detected while waiting to receive the ACK character from the host. Errors include unrecognized host commands and com- munication errors such as parity or framing errors.
Interface Related Features RS-232 Interface Features — cont. Transmission Failure Indication Enables/disables bad-label indication upon transmission failure. START / END PROGRAMMING bar codes Disable Transmission Error Indication Enable Transmission Error Indication DEFAULT Single Cable RS-232 Single Cable RS-232 Options The RS-232 Single Cable interface shares some configuration options with other RS-232 inter- faces.
Single Cable RS-232 Single Cable RS-232 RTS CTS Selection Specifies how RTS and CTS are used to control the data flow. RTS is controlled by the Scanner and can be continuously held high/low, or can be asserted during label transmission. The scan- ner looks at CTS, as the configuration values state, to determine when to send label data.
Interface Related Features Single Cable RS-232 Use BCC Enables/disables the ability of the scanner to use BCC. START / END PROGRAMMING bar codes Disable BCC Enable BCC DEFAULT Single Cable RS-232 Use ACK/NAK Enables/disables the ability of the scanner to use ACK/NAK. START / END PROGRAMMING bar codes Disable ACK/NAK...
Single Cable RS-232 Single Cable RS-232 Use STX Enables/disables the ability of the scanner to use STX. START / END PROGRAMMING bar codes Disable STX Enable STX DEFAULT Set Single Cable RS-232 STX Character This feature selects the STX character. To specify the STX Character: 1.
Interface Related Features Single Cable RS-232 Use ETX Enables/disables the ability of the scanner to use ETX. START / END PROGRAMMING bar codes Disable ETX Enable ETX DEFAULT Set Single Cable RS-232 ETX Character Allows selection of the ETX character. To specify the ETX Character: 1.
START / END PROGRAMMING bar codes Disable Pacesetter Plus DEFAULT Enable Pacesetter Plus Single Cable Datalogic Extensions Enables Datalogic extensions to the Single Cable RS-232 interface. START / END PROGRAMMING bar codes Disable Datalogic Extensions DEFAULT Enable Datalogic Extensions Product Reference Guide...
Interface Related Features USB-OEM Interface Features USB-OEM Device usage The USB-OEM protocol allows for the scanner to be identified as one of two different types of bar code scanners. Depending on what other scanners you may already have connected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate.
Single Cable RS-232 Keyboard Wedge USB Keyboard As a keyboard interface, the scanner supports most popular PCs and IBM terminals. The instal- lation of the wedge is a fairly simple process that doesn’t require any changes of software or hard- ware.
Page 74
Interface Related Features Keyboard Wedge — cont. START / END PROGRAMMING bar codes Italy Norway Portugal Spain Sweden Switzerland Japan 106 Key Hungary Czech Republic Magellan 3300HSi...
Single Cable RS-232 Keyboard Wedge — cont. START / END PROGRAMMING bar codes Slovakia Romania Croatia Poland Caps Lock State Specifies the format in which the scanner sends character data. START / END PROGRAMMING bar codes Disable Caps Lock DEFAULT Caps Lock “ON”...
Page 76
Interface Related Features Keyboard Wedge — cont. Power-On Simulation This feature does not apply to the USB Keyboard interface. NOTE All PCs check the keyboard status during the power-on Selftest. It is recommended that you enable this function if you are working without a keyboard installation. It simulates keyboard timing and passes the keyboard status to the PC during power-on.
Page 77
Single Cable RS-232 Control Characters Specifies how the scanner transmits ASCII control characters to the host. Choices are: • Disable Control Characters • Enable transmission of control characters to host • Send characters between 00H and 1FH according to a special function-key mapping table.
Page 78
Interface Related Features Keyboard Wedge — cont. Wedge Quiet Interval This feature does not apply to the USB Keyboard inter- face. NOTE Quiet Interval is the amount of time to look for keyboard activity before the scanner breaks the keyboard connection in order to transmit data to the host. START / END PROGRAMMING bar codes Selectable from 001 to 100 in 10 msec increments.
Set Intercharacter Delay USB COM Interface Set-up The scanner has two USB COM interfaces, USB COM and USB COM DL (Datalogic). The Datalogic USB-COM driver works for both USB COM interfaces. Before plugging your scanner into the Host PC, please ensure you have already copied the exe- cutable DLS-USB-COM driver file to your PC and that the scanner’s interface is set to USB...
Page 80
Interface Related Features NOTES Magellan 3300HSi...
Chapter 5 Data Editing Data Editing Overview It is not recommended to use these features with IBM interfaces. CAUTION When a bar code is scanned, additional information can be sent to the host computer along with the bar code data. This combination of bar code data and supplementary user-defined data is called a “message string.”...
Data Editing Global Prefix/Suffix START / END PROGRAMMING bar codes Sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set Prefix”...
AIM ID AIM ID AIM (Automatic Identification Manufacturers) label identifiers are assigned from a globally standardized list — as opposed to custom label ID characters you select yourself — and can be included with scanned bar code data. AIM label identifiers consist of three characters as follows: •...
Data Editing Label ID Label ID on page 153 for more information on setting this feature. START / END PROGRAMMING bar codes Label ID Position Label ID Transmission: Disable Label ID Position: Before Bar Code Data DEFAULT Label ID Position: After Bar Code Data Set UPC-A Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: A (41 hex) Set UPC-A w/P2 Addon Label ID Character(s)
Page 85
Label ID Label ID — cont. START / END PROGRAMMING bar codes Set UPC-E w/P2 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: E (45 hex) Set UPC-E w/P5 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: E (45 hex) Set UPC-E w/C128 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: E (45 hex) Set EAN-8 Label ID Character(s)
Page 86
Data Editing Label ID — cont. START / END PROGRAMMING bar codes Set EAN-13 w/P2 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: F (46 hex) Set EAN-13 w/P5 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: F (46 hex) Set EAN-13 w/C128 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: F (46 hex) Set ISBN Label ID Character(s)
Page 87
Label ID Label ID — cont. START / END PROGRAMMING bar codes Set GTIN w/C128 addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: G8 (4738 hex) Set GS1 Omnidirectional Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: R4 (5234 hex) Set GS1 Expanded Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: RX (5258...
Page 88
Data Editing Label ID — cont. START / END PROGRAMMING bar codes Set Codabar Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: % (25 hex) Set Code 93 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: & (26 hex) Set Code 11 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: @ (40 hex) Set EAN UCC Composite Label ID Character(s)
Page 89
Label ID Label ID — cont. For the 2D symbologies on this page, the Label ID is 4 bytes. The first 3 bytes are characters for the label ID. A 00 (hex) value in the first 3 bytes indicates the end of the label ID characters. The 4th byte is a control byte. The use of the control byte is as follows:...
Data Editing Case Conversion This feature can convert scanned bar code data to either all lower case (a through z) or all upper case (A through Z) characters. Case conversion affects ONLY scanned bar code data, and does not affect Label ID, Prefix, Suffix, or other appended data. NOTE START / END PROGRAMMING bar codes...
Character Conversion Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the charac- ter to convert in a pair is FF, then no conversion is done.
Chapter 6 Symbologies The scanner supports the following symbologies (bar code types). Options for each symbology are included in this chapter. • UPC-A • Code 39 • Code 32 Italian • UPC-E Pharmacode • EAN-13 • Code 128 • EAN-8 •...
Symbologies UPC-A — continued Check Digit Transmission Enable this option to transmit the check digit along with UPC-A bar code data. START / END PROGRAMMING bar codes Don’t Send Check Digit ³ Send Check Digit DEFAULT Number System Transmission This feature enables/disables transmission of UPC-A System Number. START / END PROGRAMMING bar codes Disable Number System Transmission...
UPC-A UPC-A — continued Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the sym- bology ID to match those required for EAN-13. START / END PROGRAMMING bar codes Don’t Expand to EAN-13 DEFAULT Expand to EAN-13 Product Reference Guide...
Symbologies UPC-E The following options apply to the UPC-E symbology. Disable/Enable UPC-E When disabled, the scanner will not read UPC-E bar codes. START / END PROGRAMMING bar codes Disable UPC-E Enable UPC-E DEFAULT Check Digit Transmission Enable this option to transmit the check digit along with UPC-E bar code data. START / END PROGRAMMING bar codes Don’t Send Check Digit...
UPC-E UPC-E — continued Number System Digit The Number System Digit (NSD) which is always a zero (0) in the leading position can be optionally included (or not) with scanned bar code data. START / END PROGRAMMING bar codes Exclude Number System Digit DEFAULT Include Number System Digit ³...
Symbologies UPC-E — continued Expand UPC-E to EAN13 Enables/disables expansion of UPC-E labels to EAN-13. Selecting this feature also changes the symbology ID to match those required for EAN-13. START / END PROGRAMMING bar codes Don’t Expand UPC-E to EAN-13 DEFAULT Expand UPC-E to EAN-13 Magellan...
UPC-E GTIN The following options apply to the GTIN label data format. Expand UPC/EAN to GTIN When this feature is enabled, the scanner will translate UPC/EAN labels to the 14 digit GTIN format. START / END PROGRAMMING bar codes Don’t Expand to GTIN DEFAULT Expand to GTIN Product Reference Guide...
Symbologies EAN-13 The following options apply to the EAN-13 symbology. Disable/Enable EAN-13 When disabled, the scanner will not read EAN-13 bar codes. START / END PROGRAMMING bar codes Disable EAN-13 Enable EAN-13 DEFAULT Check Digit Transmission Enable this option to transmit the check digit along with EAN-13 bar code data. START / END PROGRAMMING bar codes Don’t Send Check Digit...
EAN-13 EAN-13 — continued EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character. START / END PROGRAMMING bar codes Don’t Transmit EAN-13 Flag 1 Char Transmit EAN-13 Flag 1 Char DEFAULT ISBN When enabled, this feature truncates the leading three digits from labels that contain ISBN (International Standard Book Number) and appends an ISBN check character to the end of the label.
Symbologies EAN-8 The following options apply to the EAN-8 symbology. Disable/Enable EAN-8 When disabled, the scanner will not read EAN-8 bar codes. START / END PROGRAMMING bar codes Disable EAN-8 Enable EAN-8 DEFAULT Check Digit Transmission Enable this option to transmit the check Digit along with EAN-8 bar code data. START / END PROGRAMMING bar codes Don’t Send Check Digit...
Page 103
EAN-8 EAN-8 — continued Expands EAN-8 data to the EAN-13 data format. Selecting this fea- Expand EAN-8 to EAN-13— ture also changes the symbology ID to match those required for EAN-13. START / END PROGRAMMING bar codes Don’t Expand to EAN-13 DEFAULT Expand to EAN-13 Product Reference Guide...
Symbologies EAN Two-Label Enables/disables the ability of the scanner to decode EAN two-label pairs. START / END PROGRAMMING bar codes Disable EAN Two-Label Enable EAN Two-Label EAN Two-Label Combined Transmission Enables/disables the transmitting of an EAN two label pair as one label. START / END PROGRAMMING bar codes EAN Two-Label Combined Transmission = Disable...
Price Weight Check Digit Price Weight Check Digit Enables/disables calculation and verification of price/weight check digits. Applies to all UPC-A labels with a number-system character of 2 and EAN/JAN 13 labels with a 1 digit of 2 NOTE Here are the available options for this feature: •...
Symbologies Add-ons Add-ons (or supplemental characters) are commonly added to the end of UPC/EAN bar codes. The scanner will read the add-ons if they are enabled and in the field of view. Three add-on types are supported: 2-digit, 5-digit and Code 128 add-ons. Supported options are: This option directs the scanner to ignore add-on portion of a UPC/EAN bar code but None—...
Symbologies GS1 DataBar Omnidirectional / Stacked Omnidirectional The following options apply to the GS1 DataBar Omnidirectional symbology. Disable/Enable GS1 DataBar Omnidirectional When this feature is disabled, the scanner will not read GS1 DataBar Omnidirectional bar codes. START / END PROGRAMMING bar codes Disable GS1 DataBar Omnidirectional DEFAULT Enable GS1 DataBar Omnidirectional...
GS1 DataBar Expanded / Expanded Stacked GS1 DataBar Expanded / Expanded Stacked The following options apply to the GS1 DataBar Expanded symbology. Disable/Enable GS1 DataBar Expanded When this feature is disabled, the scanner will not read GS1 DataBar Expanded bar codes. START / END PROGRAMMING bar codes Disable GS1 DataBar Expanded...
Symbologies GS1 DataBar Expanded / Expanded Stacked — continued Length Control When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
Symbologies GS1 DataBar Limited The following options apply to the GS1 DataBar Limited symbology. Disable/Enable GS1 DataBar Limited When this feature is disabled, the scanner will not read GS1 DataBar Limited bar codes. START / END PROGRAMMING bar codes Disable GS1 DataBar Limited DEFAULT Enable GS1 DataBar Limited GS1-128 Emulation...
Code 39 Code 39 The following options apply to the Code 39 symbology. Disable/Enable Code 39 When this feature is disabled, the scanner will not read Code 39 bar codes. START / END PROGRAMMING bar codes Disable Code 39 Enable Code 39 DEFAULT Check Character Calculation When enabled, the scanner will calculate the check character of the labels.
Symbologies Check Character Transmit Enable this option to transmit the check character with scanned bar code data. START / END PROGRAMMING bar codes Disable Check Char Transmission Enable Check Char Transmission DEFAULT Start/Stop Characters Enables/disables transmission of Code39 start and stop characters. START / END PROGRAMMING bar codes Don’t Transmit Start/Stop Characters...
Code 39 Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters START / END PROGRAMMING bar codes Disable Code 39 Full ASCII DEFAULT Enable Code 39 Full ASCII Product Reference Guide...
Symbologies Code 39 — continued Length Control When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
Code 32 Italian Pharmacode Code 32 Italian Pharmacode The following options apply to the Code 32 Italian Pharmacode symbology. Disable/Enable Code 32 Italian Pharmacode When this feature is disabled, the scanner will not read Code 32 Italian Pharmacode bar codes. START / END PROGRAMMING bar codes Disable Code 32 Italian Pharmacode...
Symbologies Code 32 Italian Pharmacode — continued Check Character Transmit Enable this option to transmit the check character with scanned bar code data. START / END PROGRAMMING bar codes Disable Check Char Transmission Enable Check Char Transmission DEFAULT Magellan 3300HSi...
Code 128 Code 128 The following options apply to the Code 128 symbology. Disable/Enable Code 128 When this feature is disabled, the scanner will not read Code 128 bar codes. START / END PROGRAMMING bar codes Disable Code 128 Enable Code 128 DEFAULT Disable/Enable EAN 128 When this feature is disabled, the scanner will not read EAN 128 bar codes.
Code 128 Code 128 — continued Length Control When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
Symbologies Code 128 Conversion to Code 39 Enables/disables expansion of Code 128 labels to Code 39. START / END PROGRAMMING bar codes Disable DEFAULT Enable Interleaved 2 of 5 The following options apply to the Interleaved 2 of 5 (I 2 of 5) symbology. Disable/Enable Interleaved 2 of 5 When this feature is disabled, the scanner will not read Interleaved 2 of 5 bar codes.
Interleaved 2 of 5 Check Digit Calculation When enabled, the scanner will calculate the check digit of the labels. START / END PROGRAMMING bar codes Disable Check Digit Calculation DEFAULT Enable Check Digit Calculation Check Digit Transmit Enable this option to transmit the check digit with scanned bar code data. START / END PROGRAMMING bar codes Disable Check Digit Calculation...
Symbologies Interleaved 2 of 5 — continued Length Control When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
Codabar Codabar The following options apply to the Codabar symbology. Disable/Enable Codabar When this feature is disabled, the scanner will not read Codabar bar codes. START / END PROGRAMMING bar codes Disable Codabar DEFAULT Enable Codabar Check Character Verification When enabled, the scanner will verify the check character of the labels. START / END PROGRAMMING bar codes Disable Check Char Verification...
Symbologies Check Character Transmit Enable this option to transmit the check character with scanned bar code data. START / END PROGRAMMING bar codes Disable Check Char Transmission Enable Check Char Transmission DEFAULT Magellan 3300HSi...
Codabar Codabar — continued Length Control When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
Symbologies Codabar — continued Start/Stop Character Type Codabar has four pairs of Start/Stop patterns. Select one pair to match your application. START / END PROGRAMMING bar codes Start/Stop Type: ABCD/TN*E Start/Stop Type: ABCD/ABCD Start/Stop Type: abcd/tn*e Start/Stop Type: abcd/abcd DEFAULT Start/Stop Character Transmission The transmission of start and end characters of Codabar is selected below.
Code 93 Start/Stop Character Match This feature enables/disables the requirement that start and stop characters match START / END PROGRAMMING bar codes Disable Start/Stop Char Match DEFAULT Enable Start/Stop Char Match Code 93 The following options apply to the Code 93 symbology. Disable/Enable Code 93 When this feature is disabled, the scanner will not read Code 93 bar codes.
Symbologies Code 93 — continued Length Control When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
The following options apply to the MSI symbology. Disable/Enable MSI When this feature is disabled, the scanner will not read MSI bar codes. START / END PROGRAMMING bar codes Disable Code 93 DEFAULT Enable Code 93 MSI Check Character Transmit Enable this option to transmit the check character with scanned bar code data.
Symbologies MSI — continued MSI Check Character Calculation Enables/disables calculation and verification of optional MSI check characters. When disabled, any check characters in an MSI label are treated as data characters. START / END PROGRAMMING bar codes Disable Check Character Calculation Enable Check Character Calculation DEFAULT MSI Number of Check Characters...
MSI — continued MSI Length Control Specifies either variable-length decoding or fixed-length decoding for MSI. When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
2D Symbologies The features in this section are available ONLY for models with 2D fea- tures activated. NOTE 2D Symbologies The scanner supports the 2D symbologies (bar code types) listed below. Available options for each 2D symbology are included in this chapter. •...
2D Symbologies PDF 417 Disable/Enable PDF 417 When disabled, the scanner will not read PDF 417 bar codes. START / END PROGRAMMING bar codes Disable PDF 417 Enable PDF 417 DEFAULT Allow Zero Length PDF 417 Reading This enables/disables the scanner’s ability to read PDF417 bar codes containing a zero length codeword.
2D Symbologies PDF 417 — continued Length Control When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
2D Symbologies PDF 417 — continued PDF 417 Length 1, Length 2 Programming Instructions 1. Scan the START bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the four digits (zero-padded) representing the length.
2D Symbologies Micro PDF 417 Disable/Enable Micro PDF 417 When disabled, the scanner will not read Micro PDF 417 bar codes. START / END PROGRAMMING bar codes Disable Micro PDF 417 DEFAULT Enable Micro PDF 417 Product Reference Guide...
2D Symbologies Micro PDF 417 — continued Length Control When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
2D Symbologies Micro PDF 417 — continued Micro PDF 417 Length 1, Length 2 Programming Instructions 1. Scan the START bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the four digits (zero-padded) representing the length.
2D Symbologies Datamatrix Disable/Enable Datamatrix When disabled, the scanner will not read Datamatrix bar codes. START / END PROGRAMMING bar codes Disable Datamatrix Enable Datamatrix DEFAULT Magellan 3300HSi...
2D Symbologies Datamatrix — continued Length Control When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
2D Symbologies Datamatrix — continued Datamatrix Length 1, Length 2 Programming Instructions 1. Scan the START bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the four digits (zero-padded) representing the length.
2D Symbologies QR Code Disable/Enable QR Code When disabled, the scanner will not read QR Code labels. START / END PROGRAMMING bar codes Disable QR Code DEFAULT Enable QR Code Product Reference Guide...
2D Symbologies QR Code — continued Length Control When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
2D Symbologies QR Code — continued QR Code Length 1, Length 2 Programming Instructions 1. Scan the START bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the four digits (zero-padded) representing the length.
2D Symbologies Maxicode Disable/Enable Maxicode When disabled, the scanner will not read Maxicode labels. START / END PROGRAMMING bar codes Disable Maxicode DEFAULT Enable Maxicode Magellan 3300HSi...
2D Symbologies Maxicode — continued Length Control When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
2D Symbologies Maxicode — continued Maxicode Length 1, Length 2 Programming Instructions 1. Scan the START bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the four digits (zero-padded) representing the length.
2D Symbologies Aztec Disable/Enable Aztec When disabled, the scanner will not read Aztec labels. START / END PROGRAMMING bar codes Disable Aztec DEFAULT Enable Aztec Product Reference Guide...
2D Symbologies Aztec — continued Length Control When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
2D Symbologies Aztec — continued Aztec Length 1, Length 2 Programming Instructions 1. Scan the START bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the four digits (zero-padded) representing the length.
2D Symbologies Composite Labels Disable/Enable GS1 DataBar Omnidirectional 2D Component When enabled, if a GS1 DataBar Omnidirectional label is decoded which has the 2D linkage flag set, the 2D component must also be decoded or the base label will be discarded. When disabled, only the GS1 DataBar Omnidirectional base label will be decoded and trans- mitted regardless of the state of the linkage flag.
2D Symbologies Disable/Enable GS1 DataBar Limited 2D Component When enabled, if a GS1 DataBar Limited label is decoded which has the 2D linkage flag set, the 2D component must also be decoded or the base label will be discarded. When disabled, only the GS1 DataBar Limited base label will be decoded and transmitted regardless of the state of the linkage flag.
Advanced Decoding Features Inverse Label Reading This controls the method of reading inverse labels (white label on black background). This feature is only available for GS1 DataBar and 2D symbologies. NOTE START / END PROGRAMMING bar codes 2D Read Mode = Reads only normal labels DEFAULT 2D Read Mode = Reads both normal and inverse labels 2D Read Mode = Reads only inverse labels...
Advanced Decoding Features UPC/EAN Quiet Zone This feature sets a Quiet Zone requirement for UPC/EAN labels. START / END PROGRAMMING bar codes UPC/EAN Quiet Zone = 5 Modules UPC/EAN Quiet Zone = 3 Modules UPC/EAN Quiet Zone = 1.5 Modules Magellan 3300HSi...
Chapter 9 References This section contains explanations and examples of selected bar code features. See the program- ming sections for the actual bar code labels used to configure the scanner. Product Reference Guide...
References Global Prefix/Suffix Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/ or as a suffix (in a position following the bar code data) as indicated in Figure 1 Figure 1.
Label ID Label ID A Label ID is used to identify a bar code (symbology) type. See Appendix D, Factory Default Set- tings , for a listing for common symbologies. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs individually per symbology.
References Length Control When fixed length decoding is enabled, the scanner will decode a bar Fixed Length Decoding— code if the label length matches one of the configurable fixed lengths. When variable length decoding is enabled, the scanner will decode a Variable Length Decoding—...
Physical Properties Parameter Specification Dimensions (Scanner only): 6” x 6” x 3.42” (WxHxD) Weight (Scanner) 1 lb 4.6 oz (0.584kg) Electrical Parameters Parameters Specification AC Power Requirements AC Input: 90-264 VAC, 47~63Hz AC Power Consumption Real Power Operating (Maximum) 9.9 Watts Operating (Nominal) 3.0 Watts Sleep mode...
Appendix B Cable Pinouts Standard Cable Pinouts (Primary Interface Cables) USB, IBM Port 5B/9B/ Keyboard Pin # RS-232 USB-OEM USB Keyboard, Wedge USB COM PCCLK VBUS VBUS Line B KBCLK Line A PC Data VCC in VCC in +12V VCC in VCC in Cable Pinouts (Handheld Scanner Attached via the Aux Port) HANDHELD ATTACHED...
Appendix C Alpha-Numeric Pad Product Reference Guide...
Page 168
Alpha-Numeric Pad Note for numeric entry sequences, the scanner will announce the number of digits remaining to be entered after each label read. NOTE Magellan 3300HSi...
Appendix D Factory Default Settings Factory Defaults by Interface The following is a partial list of key settings for each interface type. RS-232 Wincor- Single USB- Keybd FEATURE Nixdorf Cable Wedge Double Read Timeout for Linear Labels 40 (400ms) 40 (400ms) 40 (400ms) 40 (400ms) 40 (400ms)
Page 170
Single Cable RS-232 Use STX Enable Set Single Cable RS-232 STX Character Single Cable RS-232 Use ETX Enable Set Single Cable RS-232 ETX Character Single Cable Pacesetter Plus Disable Single Cable Datalogic Extensions Disable USB-OEM Interface Features Config as table top scanner Magellan 3300HSi...
Page 171
Factory Defaults by Interface RS-232 Wincor- Single USB- Keybd FEATURE Nixdorf Cable Wedge IBM Transmit Labels in Code 39 Format Disable Keyboard Layout Caps Lock State Disable Power-On Simulation Disable Control Characters Disable Wedge Quiet Interval Intercharacter Delay No Delay Global Prefix/Suffix Prefix 00 Prefix 00...
Appendix E Keyboard Function Key Mappings Keyboard Model Cross Reference Table 1 summarizes the keyboard models, their defined protocol, scancode set, and some unique features. The remaining tables in this chapter provide the function key maps associated with each of the scancode sets. Table 1.
Page 176
Table 2. USB Function Key Usage Map Modifier/ ASCII Key value Usage Name Scancode 00h 44h 00h 45h GUI right Make 80h 00h GUI right Break 00h 00h CTRL right Make 10h 00h CTRL right Break 00h 00h 00h 2Ah TAB right 00h 2Bh RIGHT arrow (inner keypad)
Page 177
Keyboard Model Cross Reference Table 3 . Scanset 1 Function Key Map ASCII ASCII code Scancode (hex) ALT left Make ALT left Break CTRL left Make CTRL left Break CTRL right Make E0h 1Dh CTRL right Break E0h 9Dh TAB right RIGHT arrow (inner keypad) 4Dh + E0 TAB left...
Page 178
Table 5 Scanset 3, 102-Key Function Key Map ASCII ASCII code Scancode (hex) ALT left Make ALT left Break F0h 19h CTRL left Make CTRL left Break F0h 11h CTRL right Make CTRL right Break F0h 58h TAB right RIGHT arrow (inner keypad) TAB left 0Dh + S Enter (inner keypad)
Page 179
Keyboard Model Cross Reference Table 6. Scanset 3 122-Key Function Key Map ASCII ASCII Scancode (hex) code ALT left Make ALT left Break F0h 19h CTRL left (RESET) Make only CTRL left (RESET) Make/Break 11h F0h 11h ONLINE Enter Make only ONLINE Enter Make/Break 58h F0h 58h TAB right...
Page 180
Table 7. Japanese DOS Function Key Map ASCII value ASCII code Scancode ALT left Make ALT left Break CTRL left Make CTRL left Break CTRL right Make CTRL right Break TAB right RIGHT arrow (inner key- pad) TAB left 3Ch + S Enter (right keypad) INSERT (inner keypad) PAGE UP (inner keypad)
Page 181
Keyboard Model Cross Reference Table 8. NEC 9801-Key Function Key Map ASCII value ASCII code Scancode unused CAPS LOCK ON (make) CAPS LOCK OFF (break) CTRL left Make CTRL left Break CTRL-C TAB right RIGHT arrow (inner key- pad) TAB left 0Fh + S DELETE INSERT (inner keypad)
Appendix F Host Commands Accepting RS-232 Commands The scanner responds to the following RS-232 commands: COMMAND ASCII COMMENT Enable Scan- 0x45 Disable 0x44 Scanner Reset Scanner 0x52 Not On File 0x46 Long series of beeps Indication Beep Good 0x42 Beeps if Good Read Beep is Read Tone enabled Force Good...
2D Sample Symbols 2D Sample Symbols PDF 417 A12B3C Micro PDF 417 BV17453 Datamatrix 1314H17LL QR Code 35900G9 Maxicode MaxicodeMode4 Aztec This is an Aztec Code Product Reference Guide...
Appendix H microSD Card microSDHC Compatibility At the time of this writing, the microSD card interface for this product supports SD-Memory Card Specifications/ Part 1. Physical Layer Specification; Version 1.01, but the processor MCI can communicate with SDHC Cards. For example, the scanner can perform the functions specified in this appendix for the SDA 2.0 specification.
microSD Card Removal 1. Push in gently using your finger or thumbnail to dis- engage and remove the microSD card. Remember to keep your finger in place atop the card’s edge to avoid accidentally “launching” the card from the springloaded slot. 2.
microSD Function Details microSD Function Details From Scanner to microSD Card Capture and save an image to a microSD card by scanning a label. 1. Insert the microSD card into the scanner 2. Scan the Capture Label The scanner enters image capture mode. 3.
By scanning a label 1. Insert the microSD card into the scanner 2. Scan the status export label <FNC3>STATUS<CR> 3. Upon scanner audio indication of completion, the scanner status text file named status.txt is saved to the microSD card. By AUTORUN.DLS file 1.
microSD Function Details Configuration load to scanner By Autorun file 1. Generate a text file by any text editor as follows and save it as AUTORUN.DLS $START$ CONFIG,R96-CFG1.TEX $END$ 2. Save or copy the autorun.dls file, and copy the CPLD code (example R96-CFG1.TEX) to the microSD card 3.
Maximum label lengths will be enforced for label validation (i.e. labels longer than the maximum label size will not be validated). • Standard Datalogic formats generally use a single prefix character. The specific formats are provided below. • Suggest that handheld turn off audible and visual good read indications to minimize operator confusion.
Datalogic Handheld Data Format Requirements The following sections describe label transmission formats that are typically observed in factory configurations of Datalogic handheld scanners. RSS-14 • Prefix must be ASCII characters ‘R4’ • Check character must be included in label •...
• Prefix must be an ASCII character 'A' - total length including prefix must be greater or equal to 19 Code 128 Supplemental codes are variable length having a minimum of 2 data characters). • Characters immediately following base label must be of the form '8100', '8101' or '8102'. •...
UPC-E with 2-Digit Supplemental • Number system must be included in label data. • Check digit must be included in label data and is assumed to be correct. • Supplemental data is appended to base label. • Prefix must be an ASCII character 'E' - total length including prefix must be 11. •...
EAN-8 • Check digit must be included in label data and is assumed to be correct • Prefix must be an ASCII characters 'FF' - total length including prefix must be 10 • Example: 'FF00210126' EAN-8 with 2-Digit Supplemental • Check digit must be included in label data and is assumed to be correct.
• Example: 'F110123456789112345'. EAN-13 with Code 128 Supplemental • Check digit must be included in label data and is assumed to be correct • Supplemental data is appended to base label • Prefix must be an ASCII character 'F'- total length including prefix must be greater or equal to 20 (code 128 Supplemental codes are variable length having a minimum of 2 data characters) •...
Codabar • Check character must be included in label data. • Label length including check character and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Prefix must be an ASCII character '%'. •...
• Check character must be included in label data. • Label length including check character and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Prefix must be an ASCII character '@'. •...
AIM Formats AIM specifies a 3-character string that is attached as a prefix to the label data for transmission. Because AIM speci- fies one identifier for UPC-A, UPC-E and EAN-13 labels, UPC-A, UPC-E and EAN-13 will be received from the handheld and transmitted by the scanner as EAN-13.
5-Digit Supplemental • Supplemental data is appended to any EAN base label. • Prefix must be ASCII characters ']E2'. • Length of supplemental data including prefix must be 8. Total required length is 24 for EAN-13 and 19 for EAN-8. •...
Codabar • Check character must be included in label data. • Label length including check character and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Prefix must be ASCII characters ']F0'. •...
I 2 of 5 • Check character must be included in label data. • Label length including check characters and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. •...
ASCII Character Set The table on this page shows a set of ASCII characters and their corresponding Hex Values. The Hex Values in this table are needed for setting sym- bology specific label identifiers, as well as enabling custom prefix and suffix characters. ASCII ASCII ASCII...