Replacing the Lamp
After your lamp has been operating for 2000 hours (up to 3000 hours in Eco mode) or longer, the LAMP indicator in the
cabinet will blink red. Even though the lamp may still be working, replace it at 2000 (up to 3000 hours in Eco mode) hours
to maintain optimal projector performance. After replacing the lamp, be sure to clear the lamp hour meter. (→ User's
Manual: page 107)
CAUTION
DO NOT TOUCH THE LAMP immediately after it has been used. It will be extremely hot. Turn the projector off,
wait 30 seconds, turn off the main power switch and then disconnect the power cable. Allow at least one hour
for the lamp to cool before handling.
DO NOT REMOVE ANY SCREWS except two lamp housing screws. You could receive an electric shock.
Do not break the glass on the lamp housing.
Keep finger prints off the glass surface on the lamp housing. Leaving finger prints on the glass surface might
cause an unwanted shadow and poor picture quality.
The projector will turn off and go into standby mode after 2100 (up to 3100 hours in Eco mode) hours of service. If
this happens, be sure to replace the lamp. If you continue to use the lamp after 2000 hours (up to 3000 hours in
Eco mode) of use, the lamp bulb may shatter, and pieces of glass may be scattered in the lamp case. Do not touch
them as the pieces of glass may cause injury. If this happens, contact your NEC dealer for lamp replacement.
To replace the lamp:
Optional lamp and tools needed for replacement:
• Replacement lamp NP01LP
• Phillips screwdriver or equivalent
1. Use a Philips screwdriver to push and release the tab.
Push and pull to remove the lamp cover.
2. Loosen the two screws securing the lamp housing until the phillips screwdriver goes into a freewheel-
ing condition. The two screws are not removable.
Remove the lamp housing by holding it.
Interlock
NOTE: There is an interlock on this case to prevent the risk of electrical shock. Do not attempt to circumvent this interlock.