Meridian Nortel 1 Option 11C Technical Reference Manual page 17

Nortel networks network system technical reference guide
Hide thumbs Also See for Nortel Meridian 1 Option 11C:
Table of Contents

Advertisement

Figure 2
Flow of data during an Option 11C or Option 11C Mini Sysload
3
If the customer records cannot be located in the Backup Flash drive, the
Option 11C and 11C Mini automatically searches the PCMCIA drive. If
customer records are located and verified, data is loaded into DRAM.
4
If the customer records cannot be located in the PCMCIA drive, the
Option 11C and 11C Mini searches the Primary Flash drive for the
secondary backup (.bak) file. If the customer records are located and
verified, data is loaded into DRAM.
Sysload and a new Option 11C or Option 11C Mini installation
Software for new Option 11C and 11C Mini systems is delivered on a pre-
programmed Software Daughterboard for the Option 11C, or directly on the
MSC for the Option 11C Mini. Once this hardware is installed and the system
is powered up (SYSLOAD), the Install Setup and Loader program (LD 143)
is automatically invoked. This program is menu driven and assists in loading
the software into the system.
Memory, Storage and CPU capacity
Option 11C and 11C Mini
Page 17 of 544
Technical Reference Guide