Figure 29
Block diagram of M2317
PE Shelf
Line Pack
Pack Connector
T0
R0
Unit 0
T1
R1
Unit 1
T6
R6
Unit 6
T7
R7
Unit 7
Part of Shelf
Wiring Harness

Data communication

26
(W-BL)
1
(BL-W)
28
(W-G)
3
(G-W)
38
(BK-G)
13
(G-BK)
40
(BK-S)
16
(S-BK)
Shelf Connector
The M2317 can be equipped with an Asynchronous Data Option which will
permit the use of either the telephone's dial pad or the feature keys to place
and terminate data calls in the asynchronous mode. The Data Option also
supports keyboard dialing from the data terminal when that terminal operates
in the asynchronous mode.
M2317 Telephone
Cross-connect Block
T0
R0
T1
R1
T6
R6
T7
R7
Part of multi-pair Cable
Option 11C and 11C Mini
Page 279 of 544
TELADAPT
Connecting Block
G
Tip
Line Cord
R
Ring
to Telephone
To Telephone
To Telephone
To Telephone
553-1291
Technical Reference Guide