Meridian Nortel 1 Option 11C Technical Reference Manual page 333

Nortel networks network system technical reference guide
Hide thumbs Also See for Nortel Meridian 1 Option 11C:
Table of Contents

Advertisement

European Digital telephones: 3110, 3310, and 3820
120 V transformer The following minimum specifications must be met by
this transformer:
Input voltage
No load output voltage
Voltage at rated current
Rated load current
240 V transformer The following minimum specifications have to be met by
this transformer:
Input voltage
No load output voltage
Voltage at rated current
Rated load current
Note 1: You cannot wall mount the telephone over the wall jack when
using a transformer because of the size of the RJ-11 adapter. Hang it
above or to the side of the jack and run the line and power cords to it.
Note 2: The above-mentioned transformers can also be used with
outlets identified as 110V or 220V.
Closet Power Supply
Closet power can be obtained from an AC transformer for loops of 100 ft.
(30 m) or less, or a DC transformer for loop lengths of 650 ft. (198 m) or less.
An equivalent power source can be used but must be UL listed to provide
isolation of outputs to the terminal. See "Closet power supply configuration"
on page 305.
When using closet power, do not plug the TELADAPT connector into
any equipment other than the Meridian digital telephone, as damage to
equipment may result.
120 Vac/60 Hz
29 Vac maximum
26.7 Vac minimum
700 mA
240 Vac/50 Hz
29 Vac maximum
26.7 Vac minimum
700 mA
CAUTION
Option 11C and 11C Mini
Page 333 of 544
Technical Reference Guide