Rack-Mounting The Wlan Ip Telephony Manager 2245; Connecting To The Lan; Connecting The Power; Removing A Wlan Ip Telephony Manager 2245 - Nortel MOG6xx Installation And Configuration Manual

Wireless lan ip telephony
Table of Contents

Advertisement

Rack-mounting the WLAN IP Telephony Manager 2245

Remove the corner screws from the WLAN IP Telephony Manager 2245.
1
Screw the U-shaped end (round screw holes) of the two mounting plates to the WLAN IP
2
Telephony Manager 2245.
Screw the other end of the two mounting plates (oblong screw holes) to the rack.
3
Repeat steps 1-3 for each additional WLAN IP Telephony Manager 2245. The mounting plate
4
is designed to provide the correct minimum spacing between units. When mounting multiple
units, stack the units in the rack as closely as possible.

Connecting to the LAN

Use an RJ-45 cable to connect the NETWORK port on the WLAN IP Telephony Manager 2245
to the connecting port on the Ethernet switch.

Connecting the power

Connect the power plug from the AC adapter to the jack labeled PWR on the WLAN IP
1
Telephony Manager 2245.
Warning: Use only the provided Class II AC adapter with output 24V DC, 1A.
Plug the AC adapter into a standard AC outlet (that is, one that is compliant with local power
2
supply) to supply power to the WLAN IP Telephony Manager 2245.
The system cycles through diagnostic testing and the LEDs blink for approximately one
minute.
When the system is ready for use, verify the following:
3
The ERROR LED is off.
Status 1 is blinking.

Removing a WLAN IP Telephony Manager 2245

Disconnect the power cables and LAN cables from the WLAN IP Telephony Manager 2245.
1
Remove the failed device from the wall or rack mount.
2
WLAN IP Telephony Manager 2245 installation
43