REFRIGERANT SYSTEM DIAGRAM
MSH-XV07UV -
E1
INDOOR UNIT
Indoor coil
Indoor
thermistor
heat
RT12
exchanger
Room temperature
thermistor
RT11
MSH-XV09UV -
E1
INDOOR UNIT
Indoor coil
Indoor
thermistor
heat
RT12
exchanger
Room temperature
thermistor
RT11
Refrigerant pipe [ 9.52
(with heat insulator)
Stop valve
(with service
port)
Flared connection
Flared connection
Stop valve
Refrigerant pipe [6.35
(with heat insulator)
Refrigerant pipe [ 9.52
(with heat insulator)
Stop valve
(with service
port)
Flared connection
Flared connection
Stop valve
Refrigerant pipe [6.35
(with heat insulator)
4-way valve
Muffler
Strainer
Accumulator
Compressor
Check valve
Strainer
Capillary tube
[3.0O[1.4O600
4-way valve
Muffler
Strainer
Compressor
Check valve
Strainer
Capillary tube
[3.0O[1.4O510
11
MUH-XV07UV -
OUTDOOR UNIT
Defrost
thermistor
Outdoor
RT61
heat
exchanger
Capillary tube
[3.0O[1.4O800
Capillary tube
[3.0O[1.6O600
R.V. coil
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
MUH-XV09UV -
OUTDOOR UNIT
Defrost
Outdoor
thermistor
heat
RT61
exchanger
Capillary tube
[3.0O[1.4O800
Capillary tube
[3.0O[1.6O450
R.V. coil
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
Unit:mm
E1
(2 pcs)
Unit:mm
E1
(2 pcs)