LG DLEX4270 Series Owner's Manual page 26

Hide thumbs Also See for DLEX4270 Series:
Table of Contents

Advertisement

Available languages

Available languages

26 INSTA
LLAiTION
INSTRUCTIONS
Connecfing
Elecfric
Dryers
(conf.)
USA only
_WARNING
• Connect the power cord to the terminal
block.
Connect each power cord wire to the terminal
block screw that has the same colored
wire. For
example,
connect the black power cord wire to the
terminal
block screw with the black wire. Failure
to follow
these instructions
may result in a short,
overload,
fire or death.
• Grounding
through
the neutral
conductor
is
prohibited
for: (1) new branch-circuit
installations,
(2) mobile homes,
(3) recreational
vehicles,
and
(4) areas where local codes prohibit
grounding
through
the neutral conductor.
Three-wire
connection
for electric dryers:
Power cord
• A 3-wire connection is NOT permitted
on new
construction after January 1, 1996,
• A UL-listed strain relief is required.
1. Remove the terminal
block access cover on the
upper back of the dryer. Install a UL-listed strain relief
into the power cord through
hole; then thread a UL-
listed, 30 A, 240 V, 3-wire, #10 AWG-minimum
copper conductor power cord through
the strain
reliefl
. Use a 30 A, 240 V, UL-listed
power cord with #10
AWG-minimum
copper conductor and closed loop or
forked terminals with upturned
ends.
2 Attach the two hot leads of the power cord to the
outer terminal
block screws Attach the neutral wire to
the center terminal
block screw
Connect the external
ground
(if required by local codes) to the green
ground
screw. TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal
block access cover,
Neutral
Hot
(White)
(Black)
Screw _.1
(Red)
White
Wire
from Dryer
harness
External Ground
Wire (If required
by local codes)
JL Terminal
Block
L-Listed
train Relief
UL-Listed
3-Wire
Power
Cord