SECTION 6 – MAINTENANCE & TROUBLESHOOTING

6-1. Routine Maintenance

6-2. Overload Protection

Internal Side View
OM-1500-3 Page 20
3 Months
Replace
Damaged Or
Unreadable
Labels
6 Months
Clean
Drive
Rolls
1
Y Disconnect power
before performing
maintenance.
Y Turn Off wire feeder and weld-
1
F1 protects the wire feeder from
overload. If F1 opens the wire feeder
does not work. Correct the cause of
the fault and replace F1.
.
Close door.
.
Service unit more often if
used in severe conditions.
Replace Damaged
Gas Hose
Repair Or Replace
Cracked Cables
And Cords
Blow Out Or
Vacuum Inside
ing power source. Stop en-
gine on welding generator.
Fuse F1 (2 A, 250 V Slo-Blo)
When a fuse opens, it usually
means a more serious problem
exists, Contact a Factory Autho-
rized Service Agent.