Spark Plug(S) - Guardian 005240 Installation And Owner's Manual

7, 10, 13 and 16kw air-cooled, automatic standby generators
Hide thumbs Also See for 005240:
Table of Contents

Advertisement

Figure 4.6 — 7 kW, Engine Air Cleaner Location
3/4"
Hole
4.4.2 10KW GENERATORS
See Figure 1.2 for the location of the air cleaner. Use
the following procedure (Figure 4.7):
1. Lift the roof and remove the door.
2. Turn the worm gear clamp screw counterclock-
wise to loosen.
3. Pull the old filter off the divider panel hub.
4. Wipe away dust or debris from the panel hub.
5. Install the new air cleaner onto the hub.
6. Turn the worm gear clamp screw clockwise to
tighten.
7. Replace door and roof.
Figure 4.7 — 10kW Engine Air Cleaner
22
Section 4 — Maintenance
Air-cooled Generators
Air
Cleaner
Control
Panel
Air Filter
Figure 4.8 — 13 kW and 16 kW Engine
Air Cleaner
Screw
4.5

SPARK PLUG(S)

Reset the spark plug(s) gap or replace the spark
plug(s) as necessary. See the Service Schedule section
for maintenance requirements.
1. Clean the area around the base of the spark
plug(s) to keep dirt and debris out of the engine.
2. Remove the spark plug(s) and check the condi-
tion. Replace the spark plug(s) if worn or if reuse
is questionable. See the Service Schedule section
for recommended inspection. Clean by scraping
or washing using a wire brush and commercial
solvent. Do not blast the spark plug(s) to clean.
3. Check the spark plug gap using a wire feeler
gauge. Adjust the gap to 0.76 mm (0.030 inch) for
7 and 10kW; and 1.02 mm (0.040 inch) for 13/16
kW by carefully bending the ground electrode
(Figure 4.9).
Figure 4.9 – Setting the Spark Plug Gap
SET PLUG GAP AT 0.76 mm (.030 inch) - 7 & 10kW;
1.02 mm (.040 inch) - 13 & 16kW
Cover
Filter

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

00524300524400528300528452415280 ... Show all

Table of Contents