Parameter list
Parameter
RUN terminal
190
function selection
SU terminal
191
function selection
IPF terminal
192
function selection
OL terminal function
193
selection
FU terminal function
194
selection
195
ABC1 terminal
function selection
ABC2 terminal
196
function selection
80
Incre
Initial
Name
ments
Value
1
0
1
1
1
2
1
3
1
4
1
99
1
9999
Range
Description
0, 100: Inverter running
1, 101: Up to frequency
2, 102: Instantaneous power failure/
0 to 5, 7, 8,
undervoltage
10 to 19, 25,
3, 103: Overload warning
26, 45 to 47,
4, 104: Output frequency detection
64, 70 to 78
5, 105: Second output frequency
90 to 96, 98,
detection
99,
7, 107: Regenerative brake prealarm
100 to 105,
(Only for the 01800 or more)
107, 108,
8, 108: Electronic thermal relay function
110 to 116,
prealarm
125, 126,
10, 110: PU operation mode
145 to 147,
11, 111: Inverter operation ready
164, 170,
12, 112: Output current detection
190 to 196,
13, 113: Zero current detection
198, 199,
14, 114: PID lower limit
9999
15, 115: PID upper limit
16, 116: PID forward/reverse rotation
output
17, —: Bypass operation switchover
MC1
18, —: Bypass operation switchover
MC2
19, —: Bypass operation switchover
MC3
25, 125: Fan fault output
26, 126: Heatsink overheat pre-alarm
45, 145: Inverter running and start
command is on
46, 146: During deceleration at
occurrence of power failure
(retained until release)
47, 147: During PID control activated
64, 164: During retry
0 to 5, 7, 8,
70, 170: PID output interruption
10 to 19, 25,
71, —: Commercial-power supply side
26, 45 to 47,
motor 1 connection RO1
64, 70 to 78,
72, —: Commercial-power supply side
90, 91, 94 to
motor 2 connection RO2
96, 98, 99,
73, —: Commercial-power supply side
100 to 105,
motor 3 connection RO3
107, 108,
74, —: Commercial-power supply side
110 to 116,
motor 4 connection RO4
125, 126,
75, —: Inverter side motor 1 connection
145 to 147,
RIO1
164, 170,
76, —: Inverter side motor 2 connection
190, 191,
RIO2
194 to 196,
77, —: Inverter side motor 3 connection
198, 199,
RIO3
9999
78, —: Inverter side motor 4 connection
RIO4
90, 190: Life alarm
91, 191: Alarm output 3 (power-off signal)
92, 192: Energy saving average value
updated timing
93, 193: Current average monitor signal
94, 194: Alarm output 2
95, 195: Maintenance timer signal
96, 196: Remote output
98, 198: Minor fault output
99, 199: Alarm output
9999:No function
0 to 99: Positive logic, 100 to 199:
Negative logic