GE GCW200YAWC Series Service Manual page 37

Hide thumbs Also See for GCW200YAWC Series:
Table of Contents

Advertisement

2. Freezing failure ( Weak cooling )
Start
Error CODE
happens
on Front PCB?
Does compressor
operate?
Freezer/Compressor
cooling Fan
operate?
Temperature Fuse is
OK?
Defrost Heater is
OK?
Ice formation on
Evaporator?
No
Yes
No
Yes
Yes
Yes
Yes
Refer to Error display
No
Check the Relay wire, OLP
Fan Motor
operate?
Yes
Wire is connected?
No
No
Change the Fuse
( Left up side of Evaporator )
No
Change the Defrost Heater
No
Check ice formation and if
refrigerant leak is found, repair
36
TROUBLE SHOOTING
in Funtion page
and PTC
No
Change the relative Motor
Yes
Change Main PCB
Check lead wire
( 250W )

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents