2. Refrigerator Compartment Control
1) Adjust by the pushing the REF.SET button.
LOW - MEDIUM LOW - MEDIUM - MEDIUM MAX - MAX
2) Refrigerator Fan controlled by each mode ON/OFF point.
3) Refrigerator Compartment ON/OFF Difference : 0.5C
- MEDIUM OFF point : 5.2C
- When Room Temperature (RT) is below 13C, Refrigerator sensor OFF point 2C up ( so, MEDIUM OFF : 7.2C )
4) Weak Cooling Prevention Function
- This funtion is free of Freezer sensor.
- When refrigerator compartment reaches the Fan OFF point, the Fan is OFF.
and then Compressor controlled by Freezer sensor.
- Weak cooling temperautre is + 7C in each sensor OFF temperature.
- Weak cooling terminate temperautre is same as each sensor OFF temperature.
6) Control Temperature Point in Each Mode
Division
Display
Temperature
Normal
RT <= 13C
Weak refrigeration
Weak refrigeration
& RT <= 13C
7) SUPER REF. (QUICK) Mode : This mode runs for 40 minutes.
Freezer
Sensor
Excess
Refrigeration
OFF point
- Until the sensor reaches the Excess Refrigeration OFF point ( -7C), Refrigerator Fan and compressor is ON.
- Until the QUICK Mode ends, the appliance runs with MAX dial mode.
- After QUICK Mode ( about 40 mins ) the normal mode start.
FUNCTIONS ( TEMPERATURE CONTROL_Dispenser Model )
Initially On
4
Medium
Sensor On
5.7
Sensor Off
5.2
Sensor On
7.7
Sensor Off
7.2
Sensor On
12.2
Sensor Off
5.2
Sensor On
14.2
Sensor Off
7.2
QUICK MODE (40MIN )
1st Press
2nd Press
3
2
Medium Max
Max
4.7
3.7
4.2
3.2
6.7
5.7
6.2
5.2
11.2
10.2
4.2
3.2
13.2
12.2
6.2
5.2
10
3rd Press
4th Press
8
7
Min
Medium Min
9.7
8.7
9.2
8.2
11.7
10.7
11.2
10.2
16.2
15.2
9.2
8.2
18.2
17.2
11.2
10.2
NORMAL MODE
Start
5th Press
6th Press
6
5
7.7
6.7
7.2
6.2
9.7
8.7
9.2
8.2
14.2
13.2
7.2
6.2
16.2
15.2
9.2
8.2
ON/OFF