1.12.2 Troubleshooting flow

(1) List of troubles
a) FDT, FDTC, FDEN, FDU, FDUM, FDF series
Remote controller display
None
Operates but does not cool.
None
Operates but does not heat.
None
Earth leakage breaker activated
None
Excessive noise/vibration (1/3)
None
Excessive noise/vibration (2/3)
None
Excessive noise/vibration (3/3)
None
Louver motor failure (FDT, FDTC, FDEN, FDF series)
None
Power supply system error (Power supply to indoor control PCB)
None
Power supply system error (Power supply to remote controller)
INSPECT I/U
INSPECT I/U (When 1 or 2 remote controllers are connected)
INSPECT I/U
INSPECT I/U (Connection of 3 units or more remote controllers)
Communication error at initial operation (Models SRC40-60 only)
WAIT
Communication error at initial operation (Models FDC71-140 only)
WAIT
None
No display
E1
Remote controller communication circuit error
E5
Communication error during operation
E6
Indoor heat exchanger temperature thermistor anomaly
E7
Return air temperature thermistor anomaly
E8
Heating overload operation
E9
Drain trouble
E10
Excessive number of connected indoor units (more than 17 units) by controlling with one remote controller
E14
Communication error between master and slave indoor units
E16
Indoor fan motor anomaly
E18
Address setting error of moster and slave indoor unit
E19
Indoor unit operation check, drain motor check setting error
E20
Indoor fan motor rotation speed anomaly
E21
Defective panel switch operation (FDT only)
E28
Remote controller temperature thermistor anomaly
E35
Cooling overload operation (Models SRC40-60 only)
E35
Cooling overload operation (Models FDC71-140 only)
E36
Discharge pipe temperature error
E37
Outdoor heat exchanger temperature thermistor anomaly
E38
Outdoor air temperature thermistor anomaly
E39
Discharge pipe temperature thermistor anomaly
E40
High pressure error (63H1 activated) (Models FDC71-140 only)
E41
Power transistor overheat (Models FDC71-140 only)
E42
Current cut
E45
Communication error between inverter PCB and outdoor control PCB (Models FDC71-140 only)
E47
Inverter over-current error (Models SRC40-60 only)
E47
Inverter PCB A/F module anomaly (Model FDC71 only)
E48
Outdoor fan motor anomaly (Models SRC40-60 only)
E48
Outdoor fan motor anomaly (Models FDC71-140 only)
E49
Low pressure error or low pressure sensor anomaly (Models FDC71-140 only)
E51
Power transistor anomaly (Models SRC40-60 only)
E51
Inverter and fan motor anomaly (Models FDC71-140 only)
E53
Suction pipe temperature thermistor anomaly (Models FDC71-140 only)
E54
Low pressure sensor anomaly (Models FDC71-140 only)
E57
Insufficient refrigerant amount or detection of service valve closure (Models SRC40-60 only)
E57
Insufficient refrigerant amount or detection of service valve closure (Models FDC71-140 only)
E58
Current safe stop (Models SRC40-60 only)
E59
Compressor startup failure (Models SRC40-60 only)
E59
Compressor startup failure (Models FDC71-140 only)
E60
Anomalous compressor rotor lock (Models SRC40-60 only)
Description of trouble
363
-
-
'12 • PAC-T-173
Reference page
365
366
367
368
369
370
371
372
373
374
375
376 ‐ 378
379 ‐ 381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405・406
407
408
409
410
411
412・413
414
415
416
417
418
419
420
421
422・423
424

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents