Serial No. Definition - Philips 32TA1000/93 Service Manual

Hide thumbs Also See for 32TA1000/93:
Table of Contents

Advertisement

60
TPF1.4A LA
8.
Click Next , bring up Fig. 39.
- Click Finish to exit the Step window.
- Serial number can be filled up at this moment (for example,
923419).
NOTE: You must modify the Serial NO. In step 9, otherwise the Serial
NO. In OSD Couldn't be modified correctly.
Fig. 39
Step 5: Write DDC data
1. Configuration should be as Fig. 40. And press OK.
2. Access Factory Mode
1). Turn off monitor.
2).
Press power "
" button.Then quickly push " + " and " - "of
Volume ,and hold this two buttons , then the screen comes out
"Waiting For Automatic Adjustment ",then the screen will be black
for one second untill comes out "Windows screen"] => then
release this two buttons.
3). Press "MENU" button, wait until the OSD menu with
Characters "CHINA MAGNAVOX32 V0.2.0 051012
CLAA320WA01" (below OSD menu) come on the Screen
of the monitor(see Fig. 41).
Fig. 41
3) Push Menu to exit OSD menu.
"
"
3. Click
(Write EDID) icon from the tool bar to write DDC data.
Then wait for 20-30 seconds ,DDC data will be finished Writing.
Step 6: Save DDC data
Sometimes, you may need to save DDC data as a text file for using
in other IC chip. To save DDC data, follow the steps below:
1. Click
(Save) icon (or click "file"-> "save as") from the tool bar and
give a file name as shown in Fig. 42.
The file type is EDID46 file (*.ddc) which can be open in WordPad. By
using WordPad, the texts of DDC data & table (128 bytes, hex
code) can be modified. If DDC TEXTS & HEX Table ar completely
correct, it can be saved as *.ddc flie to re-load it into DDC IC for DDC
Data application.
8. Alignments
2.
Step 7: Exit DDC program
Fig. 40
Pull down the File menu and select Exit as shown in Fig. 43.
Step 8: Turn off the monitor, exit the factory mode.
Factory Mode
Indicator
Fig.42
Click Save.
Fig. 43

Serial NO. definition