4. Mechanical Instructions

Index of this chapter:

4.1 Assy/Panel Removal

4.2 Set Re-assembly
4.1 Assy/Panel Removal
Front view
Back view
Step 1. Remove the stand.
Remove the three screws as Fig.3 and Fig.4
Fig.3
Step 2. Remove the Back cover and Main shield assy as Fig.5~12.
a.
Remove the seven screws on the sides and the other
two screws as Fig.5
b. Use thin "I" type screwdriver to open 4 clicks on bottom
side as Fig.6
c .
Use thin "I" type screwdriver to open 2 clicks on right
side as Fig.7
e. Use thin "I" type screwdriver to open 2 clicks on left
side as Fig.8
f. Use thin "I" type screwdriver to open 6 clicks on top
side as Fig.9
g. Remove the back cover as Fig.10 .
h. Remove the 15 screws as Fig.10,Fig.11,Fig.12 , then remove the
Main shield assy.
Fig.5
4. Mechanical Instructions
Fig.1
Fig.2
Fig.4
Step 3. Remove the Scaler, HD and Power board.
Fig.6
Fig.9
Remove the 15 screws and disconnect the 10 cables as Fig. 13
and Fig.14
TPF1.4A LA
7
Fig.7
Fig.8
Fig. 10
Fig. 11
Fig. 12