Table A·1. Supported SCSI·2 Commands (continued)
Command
Opcode
Use
Use
Description
(hex)
Before
When
Spinup
Wpl
Enabled
Write
No
No
Requests Target to write the data transferred by the Intitiator to
(6-byte)
OA
the media. Both 6-byte and lO-byte (extended) formats are
(lO-byte)
2A
supported.
Write
2E
No
No
The Target perfonns a write followed by an ECC verify pass or a
And Verify
byte compare. Relative addressing not supported. (REL=O).
Write Buffer
3B
No
No
May be used to test Target's data buffer or download code. To
avoid possible data corruption, it is recommended that a
RESERVE command be executed prior to the WRITE BUFFER
command.
Write Long
3F
No
No
Allows Initiator to write one complete physical sector, including
header, data, and ECC fields.
Write Same
41
No
No
Requests the Target to write the supplied block of data to the
media a specified number of times.
Notes:
1.
WP
=
Write Protect
2. Mode Select and Mode Sense commands that do not involve saved pages may be used before spinup.
DRAFT
SCSI Command Descriptions A·5
1/18/93 09:58