Table A-1. Supported SCSI-2 Commands
Command
Opcode
Use
Use
Description
(hex)
Before
When
Spinup
Wpl
Enabled
Change
40
No
No
Requests the Target to change to the specified operating
Definition
definition. Supported definitions are SCSI (CCS) and SCSI-2.
Format Unit
04
No
No
Formats Target media into Initiator addressable logic blocks.
Defect sources include P,
0,
and G lists (no C list). When
formatting, it is recommended that the Initiator not include a
0
list (FMTDAT=O). However, if the Initiator does include a
0
list, it must be in the physical sector or bytes from index format.
The Target uses an interleave of 1 regardless of the value in
Interleave field.
Inquiry
12
Yes
Yes
Requests that information regarding Target be sent to the
Initiator. Target returns 36 bytes of SCSI Standard Product
Data. Additional Vital Product Data (VPD) may be supplied if
requested by the Initiator.
Mode Select
No
2
Yes
Provides a means for Initiator to specify media, logical unit, or
(6-byte)
15
drive parameters to Target. The following values are supported:
(to-byte)
55
• Media Type: 0
• Density Code: 0
• Number of Blocks: used to set capacity of drive
• Block Length: multiples of 1, 2, 4, 8, and 16 of blocking factor
• Page Codes (hex): 01,02,03,04,08,09, OA
Use of the following is supported:
• Disable Correction (OCR)
• Data Termination on Error (DTE)
• Post Error (PER)
Transfer Block (TB)
Retry Count
• Recovery Limit (converts to Retry Count)
Mode Sense
No
2
Yes
Provides a means for Target to report its media, logical unit, or
(6-byte)
lA
drive parameters to Initiator. The following COB values are
(IO-byte)
5A
supported:
• Page Control Field: 00 (current values); 01 (changeable
vaIues)j 10 (default values); 11 (saved values)
• Page Codes (hex): 01,02,03, 04,08,09, OA
The Target default block size is 512 bytes. Default page
parameters are listed in the MODE SENSE command
description.
Read
No
Yes' .
Requests Target to transfer data to Initiator. Both 6-byte and
(6-byte)
08
10-byte (extended) command formats are supported.
(to-byte)
28
Read Buffer
3C
No
Yes
Used with WRITE BUFFER command to test the Target's data
buffer. Recommend executing RESERVE command to guarantee
data integrity.
Notes:
1. WP
=
Write Protect
2. Mode Select and Mode Sense commands that do not involve saved pages may be used before spinup.
DRAFT
SCSI Command Descriptions A-3
1/18/93 09:58