Standard Features And Accessories; Indoor Units; Ahri* Capacity Ratings - Carrier 38GXM Product Data

Hide thumbs Also See for 38GXM:
Table of Contents

Advertisement

STANDARD FEATURES AND ACCESSORIES

Ease of Installation
Mounting Bracket
Low Voltage Controls
Comfort Features
Microprocessor Control
Wireless Remote Control
Rapid Cooling and Heating
Automatic Air Sweep
Cold Blow Prevention
Continuous Fan
Auto Restart Function
Auto Changeover
Energy Saving Features
Inverter Driven Compressor
Sleep Mode
24 Hour Stop/Start Timer
Safety And Reliability
Indoor Unit Freeze Protection
3 Minute Compressor Time Delay
High Compressor Discharge Temperature
Low Voltage Protection
Compressor Overload Protection
Compressor Over Current Protection
IPM Module Protection
Ease of Service
Cleanable Filters
Diagnostic LED's On Outdoor Board
Error Messages Displayed On Front Panel
Application Flexibility
Condensate Pumps
Standard Warranty
6 Years Compressor limited Warranty*
2 year Parts Limited Warranty*
Extended Warranty
6 --- 10 Year Compressor Only
2 --- 6 Year Parts Only
2 --- 6 Year Parts; 1 --- 6 Year Labor
2 --- 6 Year Parts; 6 --- 10 Yr Compr. Only; 1 --- 6 Yr Labor
Legend
S Standard
A Accessory
O Optional
F Field Fabricated
* For Residential applications. For Commercial applications, warranty is 1
year for parts and 5 years for compressor.

AHRI* CAPACITY RATINGS

Model Numbers
Outdoor Unit
Indoor Unit
38GXM218 --- --- ---3
2 x 40GXM009 --- --- ---3
38GXM224 --- --- ---3
2 x 40GXM012 --- --- ---3
38GXM430 --- --- ---3
4 x 40GXM009 --- --- ---3
*Air Conditioning, Heating & Refrigeration Institute
--- --- = N/A
Legend
HSPF --- Heating Seasonal Performance Factor
SEER --- Seasonal Energy Efficiency Ratio
NOTES:
1. Ratings are net values reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80_F (26.67_C) db, 67_F (19.44_C) wb air
entering indoor unit and 95_F (35_C) db air entering outdoor unit. High Temperature Heating Standard: 70_F (21.11_C) db air entering indoor unit and 47_F
(8.33_C) db, 43_F (6.11_C) wb air entering outdoor unit.
2. Ratings are based on 25 ft. (7.62 m) of interconnecting refrigerant lines.
3. All system ratings are based on fan coil units operating at high fan speed. Consult Physical Data tables for air flows at all available fan speeds.

INDOOR UNITS

S
S
S
S
S
S
S
S
S
S
S
S
On high wall fan coils, the condensate pump accessory is
S
recommended when adequate drain line pitch cannot be provided,
or when the condensate must move up to exit.
S
The pump has a lift capability of 12 ft (3.6 m) on the discharge side
S
if the pump is mounted in the fan coil or 6 ft (1.8 m) on the suction
S
side if the pump is remote mounted.
S
S
S
S
S
S
S
A
S
S
O
O
O
O
Cooling
Capacity
EER
SEER
(Btuh)
16,500
8.9
14.0
24,000
9.6
14.5
26,000
8.0
14.5
4
Fig. 1 – Condensate Pump Accessory
High Heating 47° F
Capacity (Btuh)
HSPF
18,000
7.9
27,000
8.3
28,000
8.4
A07892
Low Heating 17° F
Capacity (Btuh)
12,000
17,065
17,350

Hide quick links: