Hitachi 42EDT41A Service Manual page 11

Hide thumbs Also See for 42EDT41A:
Table of Contents

Advertisement

Plasma TV
2.2- Data Format
(1) Terminal Mode control format (Turning on and Off Terminal Mode)
- Terminal On is achieved by sending a 1 byte command of 05 (Hex).
- Terminal Off is achieved by sending a 1 byte command of 04 (Hex)
ON
/
Off
Figure. 2
(2) Terminal Communication Format (Sending Commands to TV)
-
Commands are sent to the TV in 14 byte strings
-
The strings consist of the following:
Start: 1 byte (02) Hex (STX)
Command: 12 byte
Stop: 1 Byte (03) Hex (ETX)
1
2
3
Start
Function
STX
(1 Byte)
(2 Byte)
Figure. 3
(3) Television Answer Format (Showing current Status)
-
The television responds with a 6 byte answer strings as follows:
Start: 1 byte (02) Hex (STX)
Response: 4 byte (Upper Data/Lower Data)
Stop: 1 Byte (03) Hex (ETX)
1
2
3
Start
STX
Upper Data
(1 Byte)
(2 Byte)
Figure. 4
(4) Television Answer Format (Status of Command Execution)
-
Acknowledgement: (06) Hex (ACK)
-
No Acknowledgement: (15) Hex (NAK)
ACK
/
NAK
Figure. 5
4
5
6
7
Read/Write
Function
(2 Byte)
(2 Byte)
Function (2 Byte)
4
5
6
Stop
Lower Data
ETX
(2 Byte)
(1 Byte)
11
8
9
10
11
Function
Upper Data
(2 Byte)
(2 Byte)
Function (2 Byte)
12
13
14
Stop
Lower Data
ETX
(2 Byte)
(1 Byte)
Function (2 Byte)
PW1A

Advertisement

Table of Contents
loading

Table of Contents