4.12
Water softening system
Unscrew the outside door, the base panel, the angle strip and the side
panels; unfasten the tension cords on the hinge levers; unscrew the
screws which connect the base pan to the hinge plates; unscrew the
rinsing tank from the rear panel of the base pan; separate the door
cable harness on the plug-and-socket connection in the base pan;
remove the electrical connections from the regeneration and drainage
valve; unscrew the nut which connects the salt dispenser to the
rinsing tank; draw saline solution out of the dispenser with a suction
syringe; place the appliance on its back; carefully remove the base
pan and release the catch on the level sensor housing and the water
softening system; separate the circulation pump with the rubber
support from the base pan; remove the base pan until the water
softening system can be pulled off the plug-and-socket connections
on the water inlet and the level sensor housing; pull out the reed
switch;
Note:
The following work must be carried out before the water softening
system is installed:
►
Place the seal on the filler neck of the salt dispenser.
►
Insert sealing rings into the plug-and-socket connections.
►
Put rubber cap on the bearing support in the base pan for
the pump sump.
►
Insert the switch rod for actuation of the safety level switch.
►
Fit the rubber bearing to the circulation pump.
202_58300000104305_ara_en_b – 02.11.a
Salt dispenser
Capacity:
Fine grained salt
approx. 2.0 kg
Rough-grained salt approx. 1.5 kg
Salt tablets
approx. 0.7 kg