Aqua Stop Valve - Bosch GV 630 S Repair Instructions

Table of Contents

Advertisement

4.3

Aqua Stop valve

The valve system consists of two valves in series, which are actuated
electrically parallel, and the filler valve and safety valve. The safety
function may be actuated via the safety level chamber or electrically
via the float in the base pan. The water flow is then stopped
mechanically. An electric solenoid valve which is enclosed by
a housing is attached to the tap. The housing is connected to the base
pan by a leakage water hose (sleeve of the inlet hose). The water inlet
hose, which connects the valve to the water inlet, and the electrical
control line for the solenoid valve are located inside this leakage water
hose.
Technical specifications:
Nominal voltage
Frequency
Resistance
Flow rate
Water pressure
202_58300000104305_ara_en_b – 02.11.a
230–240 V
50 Hz
2 kΩ
2.75 l/min
0.5–10 bar
A
= Solenoid valves
B
= Control cable
C
= Inlet hose
D
= Leakage-water hose
Seite 15 von 53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents