Method Of Coping With Shift Lens Error - Sony HDR-CX630V Service Manual

Hide thumbs Also See for HDR-CX630V:
Table of Contents

Advertisement

Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
Zoom operations fault
E
6
1
1
0
(Cannot initialize zoom lens.)
The abnormalities in initialization of the focus
E
6
1
1
1
lens and the abnormalities in initialization of
the zoom lens occurred simultaneously.
Reset position detection error on the stepper
E
6
1
3
0
iris initializing
Handshake correction function does not work
E
6
2
0
0
well. (With PITCH angular velocity sensor
output stopped.)
Handshake correction function does not work
E
6
2
0
1
well. (With YAW angular velocity sensor
output stopped.)
E
6
2
0
2
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller com-
E
6
2
0
3
munication abnormality among.
Image vibration correction during handshake
E
6
2
0
4
function does not work.
E
6
2
1
0
Shift lens initializing failure.
E
6
2
1
1
Shift lens overheating (Pitch)
E
6
2
1
2
Shift lens overheating (Yaw)
E
6
2
2
0
Abnormality of thermistor.
E
9
1
0
1
Abnormality when flash is beingcharged.
E
9
1
0
2
Abnormality of LED Video light.
Abnormality of LED Video light Tempera-
E
9
1
0
3
ture detection.
Battery current value goes over the max
E
9
2
0
1
discharge current
Fault of writing or erasing the flash mem-
E
9
4
0
0
ory
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
HDR-CX630V/PJ630V/PJ650E/PJ650V/PJ650VE/PJ660/PJ660E/PJ660V/PJ660VE_L2
Correction
Inspect the lens block zoom signal (pin wg, wh, rj, rk of CN4003 on
the LD-1008 board when zooming is performed when the zoom lever
is operated, and the zoom motor drive circuit (IC5501 on the LD-1008
board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Turn the power on to open lens barrier. Disconnect the battery or power
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens drive
block (pin ef, eg, ej, ek, r;, ra of CN4003 on the LD-1008 board).
If iris blades work normally, confirm that they are closing completely
and confirm following item.
・ Case of the iris blades do not close normally Replace the lens block).
・ Case of "E: 61: 30" is appeared and iris blades closed completely.
Confirm that communication with lens block is normal.
・ Case of LCD is not displayed normally Check that connection be-
tween CN6702 on CM-123 board and CN1009 on VC-1015 board
by LF-2027 flexible board.
・ Case of LCD is displayed normally Replace the lens block.
Inspect PITCH angular velocity sensors (SE7501 on the LD-1008
board) peripheral circuits.
Inspect YAW angular velocity sensors (SE7501 on the LD-1008 board)
peripheral circuits.
Refer to "1-5-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred".
Inspect the steadyshot circuit (IC5501 on the LD-1008 board).
Inspect the image vibration angular velocity sensors (SE7701 on the
OC-1002 board) peripheral circuits.
Replacement of lens block (Note 3).
If an error occurs again, replace the LD-1008 board.
Refer to "1-5-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Occurred".
Refer to "1-5-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Occurred".
Refer to "1-5-4. E : 62 : 20 (Abnormality of Thermistor) Occurred".
Check or replace the LED Flash/Video light or charging capacitor.
Check or replace the LED Flash/Video light or charging capacitor.
Check or replace the LED Flash/Video light or charging capacitor.
Check the remaining battery power because this symptom maybe
depended on the remaining battery level, and confirm whether or
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each
output of DC/DC converter (IC4301 on the VC-1015 board) with
connected the DC JACK (J901) on the VC-1015 board.
(The minimum connection to periphery)
PJ650E/PJ650V/PJ650VE:
Inspect the flash memory (IC8101 on the MM-102 board).
CX630V/PJ630V/PJ660/PJ660E/PJ660V/PJ660VE:
Inspect the flash memory (IC8101, IC8201 on the MM-102 board).
Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
E
9
4
0
1
Internal flash memory fault
E
9
4
0
2
BGM data error
E
9
5
0
0
GPS hardware error
E
9
6
0
0
Map area mount error
E
9
7
0
0
Projector hardware error

1-5. METHOD OF COPING WITH SHIFT LENS ERROR

LD-1008 BOARD (SIDE A)
Measurement points on the LD-1008 board
1-4
Correction
PJ650E/PJ650V/PJ650VE:
Inspect the flash memory (IC8101 on the MM-102 board).
CX630V/PJ630V/PJ660/PJ660E/PJ660V/PJ660VE:
Inspect the flash memory (IC8101, IC8201 on the MM-102 board).
Check the CPU (IC1301 on the VC-1015 board).
GPS Model:
Check whether the FFC-254 flexible flat cable is broken, and check
whether it is inserted imperfectly.
If there is no problem the flexible board, inspect or replacement of
the GP-037 board.
GPS Model:
Inspect or replacement of the MM-102 board.
Turn power off and turn power on again.
R5506
C5525 C5526
IC5501
C5528 C5529
Fig. 1
– ENGLISH –

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents