Product Specifi c Information
A. Appliance Certifi cation
MODELS: CD4236-MOD, CD4842-MOD
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vented Gas Fireplace
ANSI Z21.50-2014 • CSA 2.22-2014
STANDARD:
This product is listed to ANSI standards for "Vented Gas
Fireplace Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles", and "Gas Fired Appliances for
Use at High Altitudes".
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
Installation and service of this
appliance should be performed by
qualifi ed personnel. Hearth & Home
Technologies recommends HHT
Factory Trained or NFI certified
professionals.
B. Glass Specifi cations (Tempered)
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous lo-
cations such as bathtub enclosures as defi ned by the
Consumer Product Safety Commission (CPSC). The
tempered glass has been tested and certifi ed to the re-
quirements of ANSI Z97.1 and CPSC 16 CFR 1202
(Safety Glazing Certifi cation Council SGCC# 1595 and
1597. Architectural Testing, Inc. Reports 02-31919.01
and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5 "Certifi cation and labeling requirements"
which refers to 15 U.S. Code (USC) 2063 stating "...Such
certifi cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered."
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
6
Heatilator • CD4236-MOD, CD4842-MOD Owner's Manual • 2241-902 Rev. C • 11/15
C. BTU Specifi cations
Models
(U.S. or Canada)
US
(0-2000 FT)
CD4236-MOD
(NG)
CANADA
(2000-4500 FT)
US
(0-2000 FT)
CD4236-MOD
(LP)
CANADA
(2000-4500 FT)
US
(0-2000 FT)
CD4842-MOD
(NG)
CANADA
(2000-4500 FT)
US
(0-2000 FT)
CD4842-MOD
(LP)
CANADA
(2000-4500 FT)
Maximum
Minimum
Orifi ce
Input
Input
Size
BTU/h
BTU/h
(DMS)
28,000
19,000
40
25,200
17,100
41
20,000
14,000
55
18,000
12,000
56
32,000
22,000
35
28,800
19,800
36
22,000
15,000
54
20,000
14,000
55