Husky H15123TK Operator's Manual page 20

12 gallon portable air compressor
Table of Contents

Advertisement

Available languages

Available languages

2) Check that protector (A) of the brad/stapler is working
correctly. Check that is free to move in and out without
any obstruction (Fig. 13).
3) Release the outer part of cartridge (C) from the locked
position, pressing lever (D) (Fig. 14).
4) Slide the outer part of cartridge (C) downwards (Fig. 15).
5) Insert a set of nails (H) in the housing of the cartridge
(L) checking correct positioning (Fig. 16).
6) Slide the outer part of cartridge (C) upwards, pressing
lever (D) at the same time (Fig. 17).
7) Lock the outer part of cartridge (C), releasing lever
(D). Make sure that the cartridge is securely fastened
(Fig. 18).
8) Connect the brad/stapler to the compressor as
explained in the Compressor manual at chapter
"OPERATION - USING THE AIR COMPRESSOR".
9) Use the compressor regulator to adjust to the
recommended working pressure for the task to be
performed.
10) The brad/stapler is now ready for use. Before
proceeding with the actual work, it is advisable to
practice on a test piece in order to check penetration
of the nails: use a piece of reject wood of a thickness
exceeding the length of the nails. Rest point (A) of
the brad/stapler against the surface of the wood and
press trigger (B). If the nail does not penetrate to the
depth required, set the air pressure to a higher value
WITHOUT EXCEEDING THE MAXIMUM PRESSURE
INDICATED IN THIS MANUAL (Fig. 21).
11) SINGLE SEQUENTIAL MODE
This mode requires the trigger to be pulled each time a
nail is driven. The tool can be actuated by depressing
the protector (A) against the work surface followed by
pulling the trigger.
The trigger must be released to reset the tool before
another nail can be driven.
WARNING:
An improperly functioning tool must not be used.
Do not actuate the brad/stapler unless it is placed firmly
against the work piece.
MAINTENANCE
Before each use, lubricate air inlet (E) of the brad/stapler
(Fig. 12).
If a nail remains jammed inside the nail gun, comply with
the following procedure:
1) Switch off the compressor.
2) Disconnect the brad/stapler from the compressor.
3) Release the outer part of cartridge (C) from the locked
position, pressing lever (D) (Fig. 14).
4) Slide the outer part of cartridge (C) downwards (Fig. 15).
BRAD/STAPLER
A
L
20
C
D
C
H
D
C
C
D
Fig.13
Fig.14
Fig.15
Fig.16
Fig.17
Fig.18

Hide quick links:

Advertisement

Chapters

Table of Contents
loading