Error Code
Message Information
MEM0007
Message
LCD Message
Details
Action
MEM0701
Message
Details
Action
MEM0702
Message
LCD Message
Details
Action
MEM1205
Message
LCD Message
Details
Action
MEM1208
Message
LCD Message
Details
Action
Unsupported memory configuration; check memory device
at location <location>.
Unsupported memory configuration. Check memory
<location>.
The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
Correctable memory error rate exceeded for <location>.
The memory may not be operational. This an early indicator
of a possible future uncorrectable error.
Re-seat the memory modules. If the issue persists, see
Getting
Help.
Correctable memory error rate exceeded for <location>.
Correctable memory error rate exceeded for <location>. Re-
seat memory.
The memory may not be operational. This an early indicator
of a possible future uncorrectable error.
Re-seat the memory modules. If the issue persists, see
Getting
Help.
Memory mirror redundancy is lost. Check memory device at
location(s) <location>.
Memory mirror lost on <location>. Power cycle system.
The memory may not be seated correctly, misconfigured, or
has failed.
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
Memory spare redundancy is lost. Check memory device at
location <location>.
Memory spare lost on <location>. Power cycle system.
Memory sparing is no longer available.
Re-seat the memory modules. If the issue persists, see
Getting
Help.