Removing The Server From The Rack - IBM x3850 X6 Installation Instructions Manual

Hide thumbs Also See for x3850 X6:
Table of Contents

Advertisement

v Make sure that you connect the systems-management Ethernet cables to both
v Make sure that the cables are pull tight enough so the they are not too loose and
v Allow some slack in the cables to avoid strain on the cables.

Removing the server from the rack

This topic provides information on how to remove the server from the rack
cabinet.
About this task
Note: These instructions apply to both the 4U and the 8U server models. Only the
4U is shown in the illustrations.
To remove the server from the rack cabinet, complete the following steps:
1. Turn the server off.
2. Disconnect the external cables.
3. Release the cables from the cable management brackets on the server.
4. Remove the cable management bracket from the left side of the server. Press
5. Remove the shipping brackets and shipping screws from the server, if installed.
6. Remove the server components (for example, the compute books and power
16
System x3850 X6 and x3950 X6 Types 3837 and 3839: Rack Installation Instructions
nodes' IMM ports to enable communication with the IMM in both nodes.
hang below the U space to prevent them from getting pinched or damaged.
the latch outward and slide the bracket up until it is released from the server.
Remove the cable management bracket from the right side of the server.
supplies from the front and rear of the server). This reduces the weight of the
server and allow the server to be easily removed from the rack. See the server
documentation for instructions on removing the individual components from
the server.
55.4 kg
(122 lbs)
(4X)
or
32 kg
(4X)
(70 lbs)

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3950 x6

Table of Contents