Parameter Check
This function enables you to check the measurement results and equalizer characteristics after Audyssey ®
Auto Setup.
1
Use
ui
to select "Parameter Check" and then press
Auto Setup
Auto Setup
Sp. Config. Check
Parameter Check
Distance Check
Ch. Level Check
Crossover Check
EQ Check
2
ui
Use
to select the item you want to check, then press
or
p
.
Measurement results for each speaker are displayed.
Sp.Config. Check
Check the speaker configuration.
Distance Check
Check the distance.
Ch. Level Check
Check the channel level.
Crossover Check
Check the crossover frequency.
EQ Check
Check the equalizer.
• If "EQ Check" is selected, press ui to select equalizing curve ("Audyssey" or "Audyssey Flat") to
be checked.
o p
Use
to switch the display between the different speakers.
3
Press
RETURN B
.
The confirmation screen reappears. Repeat step 2.
Retrieving Audyssey ® Auto Setup settings
If you set "Restore" to "Yes", you can return to Audyssey ® Auto Setup measurement result (value
calculated at the start by MultEQ ® XT) even when you have changed each setting manually.
Set up speakers (Audyssey ® Auto Setup)
ENTER
.
Parameter Check
Sp. Config. Check
Distance Check
Ch. Level Check
Crossover Check
EQ Check
Restore