Hot Swappable Hard Drive Indicator Codes - Dell PowerEdge R430 Owner's Manual

Hide thumbs Also See for PowerEdge R430:
Table of Contents

Advertisement

Icon
Description
Temperature
indicator
Memory
indicator
PCIe indicator The indicator flashes amber

Hot swappable hard drive indicator codes

Figure 6. Hot swappable hard drive indicators
1.
hard drive activity indicator
3.
hard drive
Condition
voltage out of range, or a
failed power supply unit
(PSU) or voltage regulator).
The indicator flashes amber
if the system experiences a
thermal error (for example, a
temperature out of range or
fan failure).
The indicator flashes amber
if a memory error occurs.
if a PCIe card experiences
an error.
Corrective action
on the PSU. Reseat the PSU. If the problem
persists, see
Getting
Ensure that none of the following
conditions exist:
A cooling fan has been removed or has
failed.
System cover, cooling shroud, EMI filler
panel, memory module blank, or back
filler bracket is removed.
Ambient temperature is too high.
External airflow is obstructed.
See
Getting
help.
Check the system event log or system
messages for the location of the failed
memory. Reseat the memory module. If
the problem persists, see
Restart the system. Update any required
drivers for the PCIe card. Reinstall the card.
If the problem persists, see
2.
hard drive status indicator
help.
Getting
help.
Getting
help.