Communication operation and setting
[Fault data]
Refer to page 247 for details of fault description
Data
Definition
Data
No fault
H00
present
H10
E.OC1
H11
E.OC2
H12
E.OC3
H20
E.OV1
H21
E.OV2
H22
E.OV3
H30
E.THT

[Run command]

Instruction
Item
Code
Length
Run
HFA
command
Run
command
HF9
(expansion)
∗1 The signal within parentheses is the initial setting. The description changes depending on the setting of Pr. 180 to Pr. 182 (input terminal function selection) (page
111).
∗2 When Pr. 551 = "2" (PU mode control source is PU connector), only forward rotation and reverse rotation can be used.
[Inverter status monitor]
Instruction
Item
Code
Length
Inverter
status
H7A
monitor
Inverter
status
H79
monitor
(expansion)
∗ The signal within parentheses is the initial setting. The description changes depending on the Pr.190, Pr. 192 (output terminal function selection).
196
Definition
Data
H31
E.THM
HB0
H40
E.FIN
HB1
H52
E.ILF
HB2
H60
E.OLT
HC0
H70
E.BE
HC4
H80
E.GF
HC5
H81
E.LF
HC7
H90
E.OHT
HC9
H91
E.PTC
HF5
Bit
Description
b0: AU (terminal 4 input selection) ∗2
b1: forward rotation command
b2: reverse rotation command
b3: RL (low-speed operation
command) ∗1∗2
8bit
b4: RM (middle-speed operation
command) ∗1∗2
b5: RH (high-speed operation
command) ∗1∗2
b6: RT (second function selection)∗2
b7: MRS (output stop) ∗2
b0: AU (terminal 4 input selection) ∗2
b1: forward rotation command
b2: reverse rotation command
b3: RL (low-speed operation
command) ∗1∗2
b4: RM (middle-speed operation
16bit
command) ∗1∗2
b5: RH (high-speed operation
command) ∗1∗2
b6: RT (second function selection)∗2
b7: MRS (output stop) ∗1∗2
b8 to b15: —
Bit
Description
b0: RUN (inverter running) ∗
b1: Forward rotation
b2: Reverse rotation
b3: SU (up-to-frequency)
8bit
b4: OL (overload)
b5: —
b6: FU (frequency detection)
b7: ABC (fault) ∗
b0: RUN (inverter running) ∗
b1: Forward rotation
b2: Reverse rotation
b3: SU (up-to-frequency)
b4: OL (overload)
16bit
b5: —
b6: FU (frequency detection)
b7: ABC (fault) ∗
b8 to b14: —
b15: Fault occurrence
Fault definition display example (instruction code H74)
Definition
For read data H3010
E.PE
(Previous fault ...... THT)
E.PUE
(Latest fault...OC1)
E.RET
E.CPU
E.CDO
E.IOH
E.AIE
E.SAF
E.5
[Example 1] H02... Forward rotation
[Example 2] H00... Stop
[Example 1] H0002... Forward rotation
b15
0
0
0
0
[Example 2] H0020... Low speed operation
(When Pr. 182 RH terminal function selection
is set to "0")
b15
0
0
0
0
[Example 1] H02... During forward rotation
b7
0
[Example 2] H80... Stop at fault occurrence
b7
1
[Example 1] H0002... During forward rotation
b15
0
0
0
0
[Example 2] H8080... Stop at fault occurrence
b15
1
0
0
0
b15
b8b7
0
0
1
1 0 0 0 0
0
0
Previous fault
Latest fault
(H30)
Example
b7
b0
0
0
0
0
0
0
1
0
b7
b0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
Example
b0
0
0
0
0
0
1
0
b0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
b0
0
1
0
0
0
0
(H10)
b0
0
0
1
0
b0
0
0
0
0
b0
0
0
1
0
b0
0
0
0
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-d740-012Fr-d710w-008Fr-d720s-008

Table of Contents