Sanyo PLC-XF47 Service Manual page 39

Multimedia
Hide thumbs Also See for PLC-XF47:
Table of Contents

Advertisement

10
-3 Fan(FN915), Ducts, and Temperature switches removal.
1. Remove 2 screws-A and remove the Fan(FN915).
2. Remove 2 screws-B and remove the Duct PBS.
3. Remove 4 screws-C and remove the Ducts.
4. Remove 4 screws-D, remove the 4 temperature switches (SW903,SW904,SW905,SW906) and 4 sheets.
Note;
Mark the temperature switches as they are
removed from the optical base so that they may
be reassembled in the same location from which
they were removed.
10
-4 Holders removal.
1. Remove 2 screws-A, remove 3 screws-B and remove the Holder-A.
2. Remove 3 screws-C and remove the Holder-B.
Temperature switch
SW906
Temperature switch
SW905
Duct
D
D
C
C
FN915
A
Holder-A
- 39 -
Mechanical disassemblies
D
Temperature switch
D
SW903
Duct PBS
B
C
B
A
A
A
B
B
Holder-B
C
C
C
Sheet
Temperature switch
SW904
Duct
C
B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents