1.3.2 Technical data

Device category: II2H3+
desCriPTion
daTa naTural Gas G20 - 20 mbar:
Nominal load (gross)
Nominal capacity
Supply pressure
Burner pressure
Gas consumption *
Diameter main orifice
Diameter pilot orifice
Heating time ∆T= 44 K
daTa BuTane G30 - 30 mbar:
Nominal load (gross)
Supply pressure
Burner pressure
Gas consumption *
Diameter main orifice
Diameter pilot orifice
daTa ProPane G31 - 37 mbar
Nominal load (gross)
Supply pressure
Burner pressure
Gas consumption *
Diameter main orifice
Diameter pilot orifice
General
Storage capacity
Water connections **
Gas connection
Drain valve
Anode
T&P-plug
Maximum operating pressure
Empty weight
*
Gas consumption at 1013,25 mbar and 15°C
**
For a leak proof connection to an NPT thread, a coupling with threads to ISO 228/1 can be used.
10
unit
lG 30
k W
9.3
k W
7.4
mbar
20
mbar
12.5
m
/h
0.9
3
mm
2.35
mm
2 x 0.27
min.
45
kW
10.1
mbar
30
mbar
30
kg/h
0.7
mm
1.40
mm
0.22
kW
9.8
mbar
37
mbar
37
kg/h
0.7
mm
1.40
mm
0.22
litres
109
-
/
" - 14 NPT
3
4
-
Rp
/
1
2
-
/
" - 14 NPT
3
4
-
/
" - 14 NPT
3
4
-
/
" - 14 NPT
3
4
bar
8
kg
47
lG 40
lG 50
11.3
18.3
9.0
14.0
20
20
12.5
10.5
1.1
1.7
2.60
3.50
2 x 0.27
2 x 0.27
49
40
12.2
17.6
30
30
30
30
0.9
1.3
1.50
1.95
0.22
0.22
11.8
17.2
37
37
37
37
0.8
1.2
1.50
1.95
0.22
0.22
144
181
/
" - 14 NPT
/
" - 14 NPT
3
3
4
4
IRp
/
I
Rp
1
2
/
" - 14 NPT
/
" - 14 NPT
3
3
4
4
/
" - 14 NPT
/
" - 14 NPT
3
3
4
4
/
" - 14 NPT
/
" - 14 NPT
3
3
4
4
8
8
52
75
/
1
2

Hide quick links: