Rinnai I10 Operation Manual

Evaporative air coolers
Hide thumbs Also See for I10:

Advertisement

Quick Links

Operation Manual

I Series Evaporative Air Coolers
This appliance shall be installed in accordance with:
• Manufacturer's Installation Instructions
• Current AS/NZS 3000
• Local Regulations and Municipal Building Codes including local OH&S requirements
This appliance must be installed, maintained and removed by an Authorised Person.
For continued safety of this appliance it must be installed and maintained in
accordance with the manufacturers instructions.

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai I10

  • Page 1: Operation Manual

    Operation Manual I Series Evaporative Air Coolers This appliance shall be installed in accordance with: • Manufacturer’s Installation Instructions • Current AS/NZS 3000 • Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed, maintained and removed by an Authorised Person. For continued safety of this appliance it must be installed and maintained in accordance with the manufacturers instructions.
  • Page 2: Table Of Contents

    Shut Down ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 5 On Humid Days ��������������������������������������������������������������������������������������������������������������������������������������������������������������������� 5 Ceiling Exhaust Vent(s) ��������������������������������������������������������������������������������������������������������������������������������������������������������� 5 Wall Control Operation About Your Rinnai Programmable Wall Controller ����������������������������������������������������������������������������������������������������������������� 6 Automatic Pre-Wet ����������������������������������������������������������������������������������������������������������������������������������������������������������������� 6 Operating Modes ������������������������������������������������������������������������������������������������������������������������������������������������������������������� 6 AUTO COOL Operation Mode ������������������������������������������������������������������������������������������������������������������������������������������ 6 MANUAL Operation Mode ������������������������������������������������������������������������������������������������������������������������������������������������� 7 FAN ONLY Operation Mode ����������������������������������������������������������������������������������������������������������������������������������������������...
  • Page 3: Warnings And Important Information

    Children should be supervised to ensure that they DO NOT play with the appliance� ELECTRICAL SUPPLY CORD If the electrical supply cord is damaged, it must be replaced by Rinnai, an authorised service agent or similar qualified persons in order to avoid a hazard.
  • Page 4: Evaporative Cooler Operation

    EVAPORATIVE COOLER OPERATION INTRODUCTION Congratulations on your purchase of a Rinnai Cooling system. For you to achieve the performance and efficiency expected from your new cooler, please ensure the installer is a qualified trades person, that the installer has commissioned the unit before you commence operating, and you take the time to read the contents of this manual�...
  • Page 5: The Air Smells A Little Different, Why

    The entire process can take up to 4 minutes before cool air is expected from the duct outlets� SHUT DOWN There is a delay of up to 6 minutes after the system is turned off, during which time the Rinnai I Series Cooler performs a self clean and dry function�...
  • Page 6: Wall Control Operation

    Press the UP (5) and DOWN (6) buttons to select the comfort level you require� The longer the column shown in the Digital Display (7) the cooler the setting; the shorter the column, the warmer the setting� Benefits of using Rinnai coolers in AUTO COOL mode in preference to Manual mode •...
  • Page 7: Manual Operation Mode

    Press the TIMER button (4) to save timer setting� 4� The controller will return to the current operational screen, and the time remaining until the OFF timer activates will be displayed (e�g� OFF IN 4:00)� Rinnai I Series Evap AC OM...
  • Page 8: Zoned Systems

    Changing the mode or to turn the zone OFF can be achieved at the respective wall control. BATTERIES The Rinnai Programmable Wall Controller requires no batteries� If the digital display on the wall controller is blank, check your 240 volt power supply (at the Cooler) or check the thermostat cable�...
  • Page 9: Care & Maintenance

    COOLER SERVICE & MAINTENANCE To ensure that your Rinnai cooler continues to operate at peak efficiency, it should be serviced at two year intervals by an authorised person trained in the service of Rinnai coolers - please contact our National Care Centre, for authorised Rinnai Service Technicians�...
  • Page 10: Installation Record

    Authorised Persons - Licence Number: _____________________________________________ Installers Signature: _______________________________________________________________________ Installation Date: _______________________________________________________________________ System Details Model Number : ________________________________________________________________________ Serial Number: ________________________________________________________________________ SERVICE SCHEDULE / RECORD Service Year Service Date Service Provider Contact No. ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ Rinnai I Series Evap AC OM...
  • Page 11: Faq

    How often should the cooler be serviced? Rinnai recommend the cooler is serviced every 2 years at a minimum to ensure it operates at peak efficiency. Please Note: Due to environmental conditions the cooler may need to be serviced every year.
  • Page 12 Should water be coming out of my evaporative cooler during operation? Rinnai I Series cooler will complete a flush service once every eight hours of operation maximum. This means you may hear and/or see the unit discharge water from the primary drain pipe�...
  • Page 13: Warranty

    5 Years 5 Years 2�2 Rinnai will determine in its sole discretion, which classification the Product fits into and the corresponding Warranty that shall apply� 2�3 An Authorised Service Representative will repair or replace, at its option, the Product or any part of the Product that its examination shows to be defective�...
  • Page 14 Service or Owner’s Manual; b) complies with clause 7 below (titled "Purchaser's Responsibilities"); b) notifies Rinnai within 30 days of a defect developing, that a claim is being made under this Warranty; and c) provides, in support of the claim made under this Warranty, a Proof of Purchase�...
  • Page 15 Rinnai considers appropriate, it will authorise the Purchaser in writing to pay for the relevant freight charges, in-transit insurance expenses or travelling costs and then, upon provision by the Purchaser to Rinnai of a tax invoice showing those costs have been incurred, reimburse the Purchaser for such costs which are within the terms of the authorisation�...
  • Page 16: Contacts

    Braeside, Victoria 3195 For further information visit: www.rinnai.com.au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our National Help Line. Rinnai recommends that this appliance be serviced every 2 years.