Cd Test Mode - Pioneer deh-p7200hd Service Manual

Hide thumbs Also See for deh-p7200hd:
Table of Contents

Advertisement

5

6.2 CD TEST MODE

QQ
3 7 63 1515 0
- Flow Chart
[BAND] + [RDM] -> Reset
(P7200HD)
[3] + [DISP] -> Reset
(P5200HD)
Test Mode IN
[BAND]
Power Off
TRK
MIN
SEC
[BAND]
Power Off
TRK
MIN
SEC
[BAND]
Power Off
TRK
MIN
SEC
[BAND]
Power Off
TRK
MIN
SEC
TE
L 13942296513
*1)
TYP
TRK
MIN
SEC
*2) Focus Close
TRK
MIN
SEC
00
00
00
TRK
MIN
SEC
(
99
99
99)
*3) F.Offset Display t T.Offset Display t Switch to the
*4) 100TR Jump
*7) TRK/MIN/SEC t F.AGC t T.AGC Gain t F.Bias t RF AGC
*8) CRG motor voltage = 2 [V]
*9)
TYP (1X)
TRK
MIN
SEC
www
After the [EJECT] key is pressed keys other than the [EJECT] key should not be pressed, until disc ejection is complete.
When the key [2] or [3] is pressed during the Focus Search, the power supply should be immediately turned off (otherwise the lens sticks
to Wall, causing the actuator to be damaged).
100TR Jump, the mechanism shall be set to the Tracking Close mode when the key is released.
When the power is turned on/off the gain of the RFAMP is reset to 0 dB. At the same time all the self-adjusting values shall return to the
.
default setting.
Do not do Tracking Servo Close before doing Focus Servo Close. (Because the overcurrent flows)
5
http://www.xiaoyu163.com
[CD] or [SOURCE]
Source ON
Key of the
TRK
MIN
head unit
Key of the
[BAND]
remote
Power On
control unit
(T.Offset is adjusted)
TRK
MIN
SEC
(P7200HD)
00 00 00
[3]
[6]
Focus Close
Focus Mode switching
S curve check
*2
TRK
MIN
SEC
TRK
MIN
SEC
91 91 91
0X
0X
0X
[1]
T.Close & AGC
Applicable servomechanism
TRK
MIN
SEC
?tr ?min ?sec
[1]
[3]
*7
F,T,RF AGC
F,T AGC / F.Bias
F.Bias display switching
RF AGC
TRK
MIN
SEC
TRK
MIN
SEC
??
??
??
?tr ?min ?sec
t
t
+ 6 dB
TRK
MIN
SEC
TRK
06
06
06
12
t
t
S. Curve
F EQ measurement setting
TRK
MIN
SEC
TRK
01
01
01
order of the original display
t
t
2X
TRK
MIN
SEC
TRK
22
22
22
11
x
ao
y
i
http://www.xiaoyu163.com
6
8
NOTE
When a CD-DA (regular music CD) is played in the CD test mode, its sound quality
[Key]
will be temporarily deteriorated. The CD will then repeat normal, deteriorated,
normal... playback.
Contents
This is due to the difference in the playback modes between the normal operation
Display
mode and the CD test mode, and the interval of generating deteriorated mode and
the time taken to return to the normal mode depend on the error of each clock.
The time taken to turn to the deteriorated mode is at a minimum around 20
seconds while the time to return to the normal mode is maximum 40 seconds
approximately.
[2]
*1
RF AMP
Make sure to check the sound quality in the normal operation mode.
Gain switching
TRK
MIN
SEC
GG
GG
GG
[1]
[<]
Tracking Servo
CRG +
Close
*8
00 00 00
00 00 00
or 99 99 99
or 99 99 99
[3]
[<]
RF AGC /
CRG +
RF AGC coefficient display
TRK
MIN
SEC
8X 8X 8X
??
??
??
or 9X 9X 9X
[<]
CRG/TR Jump +
*4
TRK
MIN
SEC
?tr ?min ?sec
Q Q
3
6 7
1 3
[Key]
+ 12 dB
MIN
SEC
12
12
[BAND]
[<]
[>]
MIN
SEC
02
02
02
[1]
[2]
[3]
[6]
1X
*10)
OFF(TYP)
MIN
SEC
TRK
MIN
11
11
u163
.
DEH-P7200HD/XNUC
6
7
2 9
9 4
2 8
[>]
[2]
CRG -
Self-adjusting
*8
switching
*3
00 00 00
TRK
MIN
SEC
or 99 99 99
??
??
??
[>]
[2]
CRG -
T.Balance adjustment /
T.BAL coefficient display
8X 8X 8X
TRK
MIN
SEC
or 9X 9X 9X
??
??
??
[>]
[2]
CRG/TR Jump -
Tracking Open
*4
TRK
MIN
SEC
8X 8X 8X
?tr ?min ?sec
or 9X 9X 9X
*6
[2]
Tracking Open
8X 8X 8X
or 9X 9X 9X
1 5
0 5
8
2 9
9 4
Operation
Test Mode
Power On/Off
CRG + / TR Jump +
(Direction of the external surface)
CRG - / TR Jump -
(Direction of the internal surface)
T. CLS & AGC & Applicable servomechanism /
AGC,AGC display setting
RF Gain switching / Offset adjustment display /
T.Balance adjustment / T. Open
F. Close,S. Curve / Rough Servo and RF AGC /
F,T,RF AGC
F. Mode switching / Tracking Close
t
t
FORCUS
SEC
TRK
MIN
SEC
TRK
70
70
70
m
co
7
8
9 9
A
B
C
2 8
9 9
D
E
TRACKING
MIN
SEC
71
71
71
F
33
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Deh-p5200hd

Table of Contents