Troubleshooting - Desa CSG3924NTA Owner's Operation And Installation Manual

Unvented vent-free
Table of Contents

Advertisement

WARNING: Turn off and unplug heater and let cool before servicing.
Only a qualified service person should service and repair heater.
CAUTION: Never use a wire, needle or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM
When ignitor button is pressed,
there is no spark at ODS/
pilot
When ignitor button is pressed,
there is spark at ODS/pilot but
no ignition
22

TROUBLESHOOTING

POSSIBLE CAUSE
1. Ignitor electrode not con-
nected to ignitor cable
2. Ignitor cable pinched or
wet
3. Piezo ignitor nut is loose
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned
wrong
1. Gas supply turned off or
equipment shutoff valve
closed
2. Control knob not in PILOT
position
3. Control knob not pressed in
while in PILOT position
4. Air in gas lines when in-
stalled
5. Depleted gas supply (pro-
pane/LP only)
6. ODS/pilot is clogged
7. Gas regulator setting is not
correct
www.desatech.com
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched
by any metal or tubing.
Keep ignitor cable dry
3. Tighten nut holding piezo
ignitor to base panel of log
set. Nut is located behind
base panel
4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace pilot assembly
7. Replace pilot assembly
1. Turn on gas supply or open
equipment shutoff valve
2. Turn control knob to PILOT
position
3. Press in control knob while
in PILOT position
4. Continue holding down
control knob. Repeat ignit-
ing operation until air is
removed
5. Contact local propane/LP
gas company
6. C l e a n O D S / p i l o t ( s e e
Cleaning and Maintenance,
page 20) or replace ODS/
pilot assembly
7. Replace gas regulator
123551-01D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csg3924pt

Table of Contents