Floor Protection; Minimum Clearances To Combustible Material - Heatilator C40 Owner's Manual

Hide thumbs Also See for C40:

Advertisement

O-T L
Tested and
Portland
Listed by
Oregon USA
C
US
OMNI-Test Laboratories, Inc.
OMNI-Test Laboratories, Inc.
A division of Hearth & Home Technologies Inc.
Report #061-S-40-2
1915 W. Saunders, Mt. Pleasant, IA 52641
TESTED TO
www.heatilator.com
UL 127, ULC-S610-M87
LISTED FIREPLACE, SOLID FUEL TYPE, ALSO SUITABLE FOR MANUFACTURED
HOME INSTALLATION. (UM) 84 HUD. "For Use with Solid
Install and use only in accordance with manufacturer's installation, venting and operating instructions.
Any area incorporating warm or cold air ducts shall be enclosed in accordance with the manufacturer's
installation instructions.
Contact Your Local Building Or Fire Officials Or Authority Having Jurisdiction About Restrictions,
Installation Inspection And Permits Required In Your Area.
WARNING - For Manufactured Homes: Do not install in a sleeping room. An outside combustion air
inlet must be provided and unrestricted while unit is in use. The structural integrity of the manufactured
home floor, ceiling and walls must be maintained. The fireplace needs to be properly grounded to the
frame of the manfactured home.
Components required for installation: HTI SLSeries Pipe, Termination Cap, Hearth Extension and required
accessory Chimney Air Kit Part CAK4A.
Do not connect this unit to a chimney serving another appliance.
DANGER: Risk of electrical shock. Disconnect power supply before servicing.
Electrical Rating: 115 VAC <3.0 AMPS 60 Hz
Do not use grate or elevate fire. Build wood fire directly on firebrick.
Do not overfire. If heater or chimney connector glows, you are overfiring.
Do not use a fireplace insert or other products not specified for use with this product.
WARNING - THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET OR ANY LOG SET.
TO REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET OR ANY LOG SET INTO
FIREPLACE.
Must provide a source of air to prevent air starvation from combustion which could result of high levels of
carbon monoxide.
Replace glass only with 5mm ceramic available from your dealer.
Optional Fire Screen Part Mesh-EPA, may be used ONLY in USA
U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to comply with July 1990 particulate emission standards.
Mfg by:
www.heatilator.com
C
E
C
PA
ERTIFIED
Wood Fuel Only."
2011 2012 2013 Jan Feb Mar Apr May June July Aug Sept Oct. Nov. Dec.
DO NOT REMOVE THIS LABEL
Model:
ONSTITUTION
F
IREPLACE

Minimum Clearances To Combustible Material

Chimney sections at any level require a 2" (51mm) minimum
air space clearance between the framing and chimney section.
WITHIN ENCLOSURE AREA
Appliance to backwall
Appliance to sidewall
Duct boots to framing
Top standoffs to header
EXPOSED SURFACES
Faceplate to sidewall
Remote outlet air grills to ceiling
MANTEL
Mantel from base of fireplace
Maximum mantel depth

FLOOR PROTECTION

Combustible flooring 20" (508mm) in front of and 8" (203mm) to
either side of the fuel opening must be insulated with
non-combustible floor protection with a minimum thickness of 1"
(25mm) and ("k" value = 0.43).
In Canada: The hearth extension must be installed according to
the installation instructions.
Made in U.S.A
Serial No / Numéro De Série
009
1" (25mm)
1" (25mm)
0" (0mm)
0" (0mm")
16" (406mm)
12"(305mm)
60" (1524mm)
12" (305mm)
480-1110