Appendix A
Specifications
Physical
Maximum Working Voltage
Do not use the NI 783xR for connection to signals in Measurement Categories II,
Caution
III, or IV.
Environmental
NI 783xR User Manual
Dimensions (not including connectors)
NI PXI-783xR..................................16 cm by 10 cm (6.3 in. by 3.9 in.)
NI PCI-783xR..................................17 cm by 11 cm (6.7 in. by 4.3 in.)
I/O connectors.........................................Three 68-pin female high-density
Maximum working voltage refers to the signal voltage plus the
common-mode voltage.
Channel-to-earth .....................................±12 V, Measurement Category I
Channel-to-channel.................................±24 V, Measurement Category I
The NI 783xR is intended for indoor use only.

Operating Environment

NI 7830R, NI 7831R
40 MHz or 80 MHz timebase ..........0 °C to 55 °C, tested in
NI 7833R
40 MHz timebase.............................0 °C to 55 °C, tested in
80 MHz timebase.............................0 °C to 55 °C except the
VHDCI type
accordance with IEC-60068-2-1
and IEC-60068-2-2
accordance with IEC-60068-2-1
and IEC-60068-2-2
following: 0 °C to 45 °C when
installed in an NI PXI-1000/B or
NI PXI-101X; tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2