Customer Service; Connecting To Electrical Mains - Dometic RH 131 Operating Instructions Manual

Minibar
Hide thumbs Also See for RH 131:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
GB

12. Customer service

Before you call a service engineer, carry out the
following simple tests:
Problem
The appliance does not
cool sufficiently
The appliance does not
cool at all
If after checking all the above points, the refrigerator is
still not working satisfactorily, contact your nearest
service engineer. State the problem, model, product-
and serial-number.
(Details of the model, product- and serialnumber are
to be found on the data label in the top left of the
inside compartment.)
Refrigerators until serial number 634xxxxx are
equipped with overheating protection on the cooling
unit. An authorised service technician can check
whether this has been triggered or not.
Refrigerators from serial number 634xxxxx, instead of
having overheating protection, are equipped with a
second (evaporator) sensor.
In the event of a fault developing, contact your nearest
Service Centre-see local telephone directory.
www.dometic.com
13. Putting into operation
Technical data:
Model
RH 131
Type
MF20-60
Gross volume
31 litre
Mains operation
220 - 240V (AC)
Input
65W
Energy consumption*
0.730 kWh/24h
Climate class
N
Refrigerant
159g H
* The energy consumption is measured at 12°C at 25°C
environment temperature ( cellar ).

13.1. Connecting to electrical mains

The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected to
a mains socket earthed in accordance with
regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
8
Possible cause
Thermostat control is set too low
Too much food to be cooled was put in
Door is not shut properly.
Refrigerator not level
Internal air circulation is restricted.
External air circulation is restricted.
CUC system stopped the operation
Plug is not connected to the mains
socket properly.
There is no voltage in the mains socket
RH 141
MF20-60
41 litre
220 - 240V (AC)
65W
0,750 kWh/24h
N
O+86g NH
159g H
O+86g NH
2
3
2
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity
supply voltage is the same as that indicated on the
appliance rating plate.
Only for UK:
The appliance is supplied with a 3 amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 3 amp ASTA approved (BS 1362) fuse
must be used. Should the plug need to be replaced
for any reason, the wires in the mains lead are
coloured in accordance with the following code:
Green and Yellow:
3
Blue:
Brown:
The wire coloured green and yellow must be
connected to the terminal marked with the letter „E"
or by the earth symbol
yellow.
The wire coloured blue must be connected to the
terminal „N" or coloured black.
The wire coloured brown must be connected to the
terminal marked „L" or coloured red.
Solution
Set to a higher position
Put in less food to be be cooled
Check if the door is shut
Level refrigerator
Provide inside cool air circulation.
Provide outside air circulation.
See operating instruction 5. 2.
Check if the connection is proper.
Check if there is voltage.
(eg. Connect a lamp to the socket)
Earth
Neutral
Live
or coloured green and