Flame Adjustment; Flame Characteristics; Maintenance - Napoleon GDI30 Installation And Operating Instructions Manual

Napoleon fireplaces vented gas fireplace heater installation and operating instructions
Table of Contents

Advertisement

18
7.3

FLAME ADJUSTMENT

Turn counter-
clockwise to
decrease fl ame
height
7.4

FLAME CHARACTERISTICS

It's important to periodically perform a visual check of the pilot and burner
fl ames. Compare them to the illustrations provided. If any fl ames appear
abnormal call a service person.

8.0 MAINTENANCE

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing. This fi replace and its venting system
should be inspected before use and at least annually by a qualifi ed service person. The fi replace area must
be kept clear and free of combustible materials, gasoline or other fl ammable vapors and liquids. The fl ow of
combustion and ventilation air must not be obstructed.
1.
In order to properly clean the burner and pilot assembly, remove the logs, rocks and/or glass to
expose both assemblies.
2.
Keep the control compartment, media, burner, air shutter opening and the area surrounding the logs
clean by vacuuming or brushing, at least once a year.
3.
Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or
are not burning properly.
4.
Check to see that the pilot fl ame is large enough to engulf the fl ame sensor and/or thermocouple /
thermopile as well as reaches the burner.
5.
Replace the cleaned logs, rocks or glass. Failure to properly position the media may cause carboning
which can be distributed in the surrounding living area.
6.
Check to see that the main burner ignites completely on all openings when turned on. A 5 to 10
second total light-up period is satisfactory. If ignition takes longer, consult your local authorized dealer /
distributor.
7.
Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if
necessary.
8.
If for any reason the vent air intake system is disassembled, re-install and re-seal per the instructions
provided for the initial installation.
W415-0806 / 06.28.09
Turn clockwise
to increase fl ame
height
MAINTENANCE
MAINTENANCE
WARNING
MAINTENANCE
!
FLAME ADJUSTMENT KNOB
3/8" - 1/2"
FLAME MUST
ENVELOPE UPPER
3/8" TO 1/2" OF
THERMOCOUPLE &
THERMOPILE
54.2
40.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gdi-30nGdi-30p

Table of Contents