Napoleon GDIZC-N Installation And Operation Instructions Manual

Napoleon GDIZC-N Installation And Operation Instructions Manual

Gas-fired direct vent insert vented gas fireplace heater natural & propane gas models

Advertisement

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS
GAS-FIRED DIRECT VENT INSERT
INSTALLATION AND OPERATION INSTRUCTIONS FOR:
WARNING: If the information in these instructions is not followed exactly, a fi re or
explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other fl ammable vapours and liquids in the vicinity of
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
Installation and service must be performed by a qualifi ed installer, service
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada (705)721-1212 fax (705)722-6031
VENTED GAS FIREPLACE HEATER
NATURAL GAS MODELS
PROPANE GAS MODELS
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS
FOR YOUR SAFETY
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
agency or the gas supplier.
www.napoleonfireplaces.com ask@napoleon.on.ca
GDIZC - N
GDIZC - P
• Immediately call your gas supplier from
a neighbour's phone. Follow the gas sup-
plier's instructions.
• If you cannot reach your gas supplier,
call the fi re department.
1
W415-0223 / E / 03.05.09

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon GDIZC-N

  • Page 1 INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS GAS-FIRED DIRECT VENT INSERT INSTALLATION AND OPERATION INSTRUCTIONS FOR: VENTED GAS FIREPLACE HEATER NATURAL GAS MODELS PROPANE GAS MODELS CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS...
  • Page 2: Table Of Contents

    W415-0223 / E / 03.05.09 TABLE of CONTENTS Pg 9 12-13 REPLACEMENTS 14-15 TROUBLE SHOOTING GUIDE WARNING OPERATION / MAINTENANCE Operating Instructions Maintenance REPLACEMENT BLOWER ADJUSTMENTS Pilot Burner Adjustment Vent Restrictions Venturi Adjustments Ordering Replacement Parts Replacement Parts Terminal Kits Accessories SERVICE HISTORY...
  • Page 3 NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The complete fi replace is thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON.
  • Page 4: General Instructions

    Sites and Community Standard ANSI/NFPA 501A in the United States. Purge all gas lines with the glass door of the fi replace insert opened. Assure that a continuous gas fl ow is at the burner before closing the door. Under extreme vent confi gurations, allow several minutes (5-15) for the fl...
  • Page 5: Installation

    Provide adequate ventilation air. Provide adequate accessibility clearance for servicing and operating the fi replace insert. Never obstruct the front opening of the fi replace insert. Objects placed in front of the fi replace must be kept a minimum of 48" away from the front face of the unit. FIGURES 1a-c 3 SIDED BACKER PLATE ALUMINUM TRIM...
  • Page 6: Insert Vent Connection

    INSERT VENT CONNECTION Move the insert close to its fi nal position inside the wood- burning fi replace. This unit is equipped with 6 levelling screws located as follows: two are on either side of the circulation blower on the rear panel; four are located front and back on either side beneath the log support.
  • Page 7: Wall Switch / Thermostat

    WALL SWITCH / THERMOSTAT For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2-strand solid core millivolt wire from the gas fi replace insert to the wall switch / millivolt thermostat.
  • Page 8: Log Placement

    GLOWING EMBERS 4. Tear the glowing embers into pieces and place along the front row of ports covering all of the burner area in front of the logs. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fi bre hairs will glow.
  • Page 9: Operation / Maintenance

    The on-off switch is located behind the left side control door. Purge all gas lines with the glass door open. Assure that a continuous gas fl ow is at the burner before closing the door. Allow several minutes (5-15) for the fl ame to stabilize after ignition.
  • Page 10 OPTIONAL BLOWER INSTALLATION FIGURE 21 1. Turn off the electrical power and the gas supply to the fi replace insert. 2. Remove the fi re viewing door. Remove the logs. FIGURE 22 3. Detach the two screws from the back of the fi rebox and remove the panel, as illustrated.
  • Page 11: Adjustments

    Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for the fi...
  • Page 12: Replacements

    REPLACEMENT PARTS W725-0039 RBT SHAW VALVE - NG W725-0040 RBT SHAW VALVE - LP W100-0068 BURNER W455-0017 #42 BURNER ORIFICE - NG W455-0059 #53 BURNER ORIFICE - LP W010-0800 PILOT ASSEMBLY - LP W010-0801 PILOT ASSEMBLY - NG W455-0069 PILOT INJECTOR - NG...
  • Page 13 W415-0223 / E / 03.05.09 WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
  • Page 14: Trouble Shooting Guide

    Faulty thermostat or switch W415-0223 / E / 03.05.09 PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor.
  • Page 15 SYMPTOM PROBLEM REFER TO "MAIN BURNER GOES OUT; PILOT STAYS ON" Main burner goes out; pilot goes out. Vent re-circulating Thermocouple shorting or faulty. Vent is reversing Exhaust fumes smelled Fireplace is spilling. in room, headaches. Carbon is being de-...
  • Page 16 43.1 W415-0223 / E / 03.05.09...