Operation Data - Carrier 42NQV050M Service Manual

Split type indoor and outdoor unit
Hide thumbs Also See for 42NQV050M:
Table of Contents

Advertisement

7-2. Operation Data

<Cooling>
Tempeature
Model name
condition(°C)
Indoor
Outdoor
27/19
35/-
42NQV050M
42NQV060M
<Heating>
Tempeature
Model name
condition(°C)
Indoor
Outdoor
20/-
7/6
42NQV050M
42NQV060M
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchaner path U bent.
(Thermistor themometer)
2. Connecting piping condition 7.5 m
Standard
Heat exchanger
pressure
pipe temp.
P (MPa)
T1 (°C)
0.9 to 1.1
11 to 13
0.9 to 1.1
11 to 13
Standard
Heat exchanger
pressure
pipe temp.
P (MPa)
T1 (°C)
2.5 to 2.6
40 to 42
2.6 to 2.8
42 to 44
– 20 −
Indoor
fan mode
T2 (°C)
40 to 42
High
41 to 43
High
Indoor
fan mode
T2 (°C)
1 to 3
High
0 to 2
High
Outdoor
Compressor
fan mode
revolution
(rps)
High
67
High
77
Outdoor
Compressor
fan mode
revolution
(rps)
High
79
High
84